Literature DB >> 11979573

MR temperature measurement in liver tissue at 0.23 T with a steady-state free precession sequence.

D Germain1, E Vahala, G J Ehnholm, T Vaara, M Ylihautala, M Savart, A Laurent, J Tanttu, H Saint-Jalmes.   

Abstract

MRI can be used for monitoring temperature during a thermocoagulation treatment of tumors. The aim of this study was to demonstrate the suitability of a 3D steady-state free precession sequence (3D Fast Imaging with Steady-State Precession, 3D TrueFISP) for MR temperature measurement at 0.23 T, and to compare it to the spin-echo (SE) and spoiled 3D gradient-echo (3D GRE) sequences. The optimal flip angle for the TrueFISP sequence was calculated for the best temperature sensitivity in the image signal from liver tissue, and verified from the images acquired during the thermocoagulation of excised pig liver. Factors influencing the accuracy of the measured temperatures are discussed. The TrueFISP results are compared to the calculated values of optimized SE and 3D GRE sequences. The accuracy of TrueFISP in the liver at 0.23 T, in imaging conditions used during thermocoagulation procedures, is estimated to be +/-3.3 degrees C for a voxel of 2.5 x 2.5 x 6 mm(3) and acquisition time of 18 s. For the SE and GRE sequences, with similar resolution and somewhat longer imaging time, the uncertainty in the temperature is estimated to be larger by a factor of 2 and 1.2, respectively. Copyright 2002 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2002        PMID: 11979573     DOI: 10.1002/mrm.10147

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

Review 1.  MR thermometry.

Authors:  Viola Rieke; Kim Butts Pauly
Journal:  J Magn Reson Imaging       Date:  2008-02       Impact factor: 4.813

2.  Temperature imaging of laser-induced thermotherapy (LITT) by MRI: evaluation of different sequences in phantom.

Authors:  Babak Bazrafshan; Frank Hübner; Parviz Farshid; Renate Hammerstingl; Jijo Paul; Vitali Vogel; Werner Mäntele; Thomas J Vogl
Journal:  Lasers Med Sci       Date:  2013-03-28       Impact factor: 3.161

3.  Hybrid proton resonance frequency/T1 technique for simultaneous temperature monitoring in adipose and aqueous tissues.

Authors:  Nick Todd; Mahamadou Diakite; Allison Payne; Dennis L Parker
Journal:  Magn Reson Med       Date:  2012-03-05       Impact factor: 4.668

4.  MR imaging-guided laser ablation of osteoid osteomas with use of optical instrument guidance at 0.23 T.

Authors:  Roberto Blanco Sequeiros; Pekka Hyvönen; Alberto Blanco Sequeiros; Lasse Jyrkinen; Risto Ojala; Rauli Klemola; Teuvo Vaara; Osmo Tervonen
Journal:  Eur Radiol       Date:  2003-05-07       Impact factor: 5.315

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.