Literature DB >> 11973427

Quantitative T(1rho) and magnetization transfer magnetic resonance imaging of acute cerebral ischemia in the rat.

Heidi I Mäkelä1, Mikko I Kettunen, Olli H J Gröhn, Risto A Kauppinen.   

Abstract

It has been previously shown that T1 in the rotating frame (T(1rho)) is a very sensitive and early marker of cerebral ischemia and that, interestingly, it can provide prognostic information about the degree of subsequent neuronal damage. In the present study the authors have quantified T(1rho) together with the rate and other variables of magnetization transfer (MT) associated with spin interactions between the bulk and semisolid macromolecular pools by means of Z spectroscopy, to examine the possible overlap of mechanisms affecting these magnetic resonance imaging contrasts. Substantial prolongation of cerebral T(1rho) was observed minutes after induction of ischemia, this change progressing in a time-dependent manner. Difference Z spectra (contralateral nonischemic minus ischemic brain tissue) showed a significant positive reminder in the time points from 0.5 to 3 hours after induction of ischemia, the polarity of this change reversing by 24 hours. Detailed analysis of the MT variables showed that the initial Z spectral changes were due to concerted increase in the maximal MT (+3%) and amount of MT (+4%). Interestingly, the MT rates derived either from the entire frequency range of Z spectra or the time constant for the first-order forward exchange (k(sat)) were unchanged at this time, these variables reducing only one day after induction of ischemia. The authors conclude that T(1rho) changes in the acute phase of ischemia coincide with both elevated maximal MT and amount of MT. These changes occur independent of the overall MT rate and in the absence of net water gain to the tissue, whereas in the consolidating infarction the decrease in the rate and amount of MT, as well as the extensive prolongation of T(1rho), are associated with water accumulation.

Entities:  

Mesh:

Year:  2002        PMID: 11973427     DOI: 10.1097/00004647-200205000-00006

Source DB:  PubMed          Journal:  J Cereb Blood Flow Metab        ISSN: 0271-678X            Impact factor:   6.200


  18 in total

1.  Improving the detection sensitivity of pH-weighted amide proton transfer MRI in acute stroke patients using extrapolated semisolid magnetization transfer reference signals.

Authors:  Hye-Young Heo; Yi Zhang; Tina M Burton; Shanshan Jiang; Yansong Zhao; Peter C M van Zijl; Richard Leigh; Jinyuan Zhou
Journal:  Magn Reson Med       Date:  2017-06-21       Impact factor: 4.668

2.  Dynamics of paramagnetic agents by off-resonance rotating frame technique in the presence of magnetization transfer effect.

Authors:  Huiming Zhang; Yang Xie
Journal:  J Magn Reson       Date:  2006-11-22       Impact factor: 2.229

Review 3.  A review of optimization and quantification techniques for chemical exchange saturation transfer MRI toward sensitive in vivo imaging.

Authors:  Jinsuh Kim; Yin Wu; Yingkun Guo; Hairong Zheng; Phillip Zhe Sun
Journal:  Contrast Media Mol Imaging       Date:  2015-01-12       Impact factor: 3.161

4.  Imaging of amide proton transfer and nuclear Overhauser enhancement in ischemic stroke with corrections for competing effects.

Authors:  Hua Li; Zhongliang Zu; Moritz Zaiss; Imad S Khan; Robert J Singer; Daniel F Gochberg; Peter Bachert; John C Gore; Junzhong Xu
Journal:  NMR Biomed       Date:  2014-12-07       Impact factor: 4.044

5.  Investigation of optimizing and translating pH-sensitive pulsed-chemical exchange saturation transfer (CEST) imaging to a 3T clinical scanner.

Authors:  Phillip Zhe Sun; Thomas Benner; Ashok Kumar; A Gregory Sorensen
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

6.  Magnetization transfer contrast MRI for non-invasive assessment of innate and adaptive immune responses against alginate-encapsulated cells.

Authors:  Kannie W Y Chan; Guanshu Liu; Peter C M van Zijl; Jeff W M Bulte; Michael T McMahon
Journal:  Biomaterials       Date:  2014-06-13       Impact factor: 12.479

7.  Rapid acquisition strategy for functional T1ρ mapping of the brain.

Authors:  Casey P Johnson; Hye-Young Heo; Daniel R Thedens; John A Wemmie; Vincent A Magnotta
Journal:  Magn Reson Imaging       Date:  2014-08-02       Impact factor: 2.546

8.  Quantitative assessment of water pools by T 1 rho and T 2 rho MRI in acute cerebral ischemia of the rat.

Authors:  Kimmo T Jokivarsi; Juha-Pekka Niskanen; Shalom Michaeli; Heidi I Gröhn; Michael Garwood; Risto A Kauppinen; Olli H Gröhn
Journal:  J Cereb Blood Flow Metab       Date:  2008-10-01       Impact factor: 6.200

9.  pH-sensitive MRI demarcates graded tissue acidification during acute stroke - pH specificity enhancement with magnetization transfer and relaxation-normalized amide proton transfer (APT) MRI.

Authors:  Yingkun Guo; Iris Yuwen Zhou; Suk-Tak Chan; Yu Wang; Emiri T Mandeville; Takahiro Igarashi; Eng H Lo; Xunming Ji; Phillip Zhe Sun
Journal:  Neuroimage       Date:  2016-07-19       Impact factor: 6.556

10.  Quantitative assessment of demyelination in ischemic stroke in vivo using macromolecular proton fraction mapping.

Authors:  Marina Y Khodanovich; Alena A Kisel; Andrey E Akulov; Dmitriy N Atochin; Marina S Kudabaeva; Valentina Y Glazacheva; Michael V Svetlik; Yana A Medvednikova; Lilia R Mustafina; Vasily L Yarnykh
Journal:  J Cereb Blood Flow Metab       Date:  2018-01-26       Impact factor: 6.200

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.