Literature DB >> 11972470

MR imaging of the neural foramina of the cervical spine. Comparison of 3D-DESS and 3D-FISP sequences.

Claus Muhle1, J M Ahn, J Biederer, F K W Schäfer, C H Frahm, A Mohr, J Brossmann, D Resnick.   

Abstract

PURPOSE: To assess whether a single three-dimensional double-echo steady state (3D-DESS) sequence can produce equivalent results when compared to a 3D free induction with steady precession (3D-FISP) sequence for the evaluation of the neural foraminal diameter and structures.
MATERIAL AND METHODS: Five phantoms were imaged on CT with 3-mm axial slices followed by reformatted axial 3D-DESS and 3D-FISP sequences. In addition, 3D-DESS and 3D-FISP sequences of 20 healthy subjects were compared with regard to image quality, differentiation between vertebrae and discs, differentiation between discs and neural foramina, and differentiation between vertebrae and neural foramina.
RESULTS: Compared with CT, 3D-DESS and 3D-FISP sequences consistently underestimated the diameters of the neural foramina. The mean difference values for the 3D-DESS was 12.8%, compared to 9.5% for the 3D-FISP sequence. Concerning the in vivo studies, the 3D-DESS sequence was superior but not statistical significant to the 3D-FISP sequence with regard to image quality, differentiation between vertebrae and discs, differentiation between discs and neural formina, and identification of the nerve roots.
CONCLUSION: The 3D-DESS sequence is moderately accurate in the evaluation of the neural foraminal size. Compared to the 3D-FISP sequence, the 3D-DESS sequence is compatible concerning the image quality, differentiation between the cervical vertebrae and discs, and between the discs and neural foramina.

Entities:  

Mesh:

Year:  2002        PMID: 11972470     DOI: 10.1080/028418502127347510

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.701


  5 in total

1.  Three-dimensional true FISP for high-resolution imaging of the whole brain.

Authors:  B Schmitz; T Hagen; W Reith
Journal:  Eur Radiol       Date:  2003-02-26       Impact factor: 5.315

2.  Three-dimensional sampling perfection with application-optimised contrasts using a different flip angle evolutions sequence for routine imaging of the spine: preliminary experience.

Authors:  B Tins; V Cassar-Pullicino; M Haddaway; U Nachtrab
Journal:  Br J Radiol       Date:  2012-02-28       Impact factor: 3.039

3.  MRI of the lumbar spine at 7 Tesla in healthy volunteers and a patient with congenital malformations.

Authors:  Astrid E Grams; Oliver Kraff; Lale Umutlu; Stefan Maderwald; Philipp Dammann; Mark E Ladd; Michael Forsting; Elke R Gizewski
Journal:  Skeletal Radiol       Date:  2011-05-24       Impact factor: 2.199

4.  Ultrashort echo time Cones double echo steady state (UTE-Cones-DESS) for rapid morphological imaging of short T2 tissues.

Authors:  Hyungseok Jang; Yajun Ma; Michael Carl; Saeed Jerban; Eric Y Chang; Jiang Du
Journal:  Magn Reson Med       Date:  2021-03-23       Impact factor: 3.737

5.  Diagnostic agreement between 3.0-T MRI sequences of nerve root and surgery in patients with cervical radiculopathy: A retrospective study.

Authors:  Qi Wang; Huixia Li; Jianjun Kong; Xiaohui Li; Lin Feng; Zhanyong Wu
Journal:  Medicine (Baltimore)       Date:  2021-01-29       Impact factor: 1.817

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.