BACKGROUND: The majority of port-wine stain (PWS) patients treated with the pulsed dye laser (PDL) do not achieve complete blanching. Safe administration of higher fluences has been proposed as a means of improving treatment efficacy. OBJECTIVE: To determine the safety and efficacy of PWS treatment with the 1.5-msec PDL at high fluences in conjunction with cryogen spray cooling. METHODS: Twenty PWS patients were treated with the PDL in combination with cryogen spray cooling utilizing a 7 or 10 mm spot size and fluences ranging from 6 to 15 J/cm2. Before and after treatment photographs were compared on a blinded basis. RESULTS: No scarring or skin textural changes occurred. Blanching scores were as follows: 20% of patients achieved 75% or greater blanching after an average of 3.3 treatments, 30% achieved 50-74% blanching, 20% achieved 25-49% blanching, and 30% achieved less than 25% blanching. CONCLUSION: In conjunction with cryogen spray cooling, the PDL can be safely used at high fluences. At this time it is not clear that the use of higher fluences improves treatment efficacy; however, as other aspects of PWS laser treatment are optimized, safe administration of higher fluences is likely to be advantageous.
BACKGROUND: The majority of port-wine stain (PWS) patients treated with the pulsed dye laser (PDL) do not achieve complete blanching. Safe administration of higher fluences has been proposed as a means of improving treatment efficacy. OBJECTIVE: To determine the safety and efficacy of PWS treatment with the 1.5-msec PDL at high fluences in conjunction with cryogen spray cooling. METHODS: Twenty PWSpatients were treated with the PDL in combination with cryogen spray cooling utilizing a 7 or 10 mm spot size and fluences ranging from 6 to 15 J/cm2. Before and after treatment photographs were compared on a blinded basis. RESULTS: No scarring or skin textural changes occurred. Blanching scores were as follows: 20% of patients achieved 75% or greater blanching after an average of 3.3 treatments, 30% achieved 50-74% blanching, 20% achieved 25-49% blanching, and 30% achieved less than 25% blanching. CONCLUSION: In conjunction with cryogen spray cooling, the PDL can be safely used at high fluences. At this time it is not clear that the use of higher fluences improves treatment efficacy; however, as other aspects of PWS laser treatment are optimized, safe administration of higher fluences is likely to be advantageous.
Authors: Jennifer K Chen; Pedram Ghasri; Guillermo Aguilar; Anne Margreet van Drooge; Albert Wolkerstorfer; Kristen M Kelly; Michal Heger Journal: J Am Acad Dermatol Date: 2012-02-03 Impact factor: 11.527
Authors: Bernard Choi; Wenbin Tan; Wangcun Jia; Sean M White; Wesley J Moy; Bruce Y Yang; Jiang Zhu; Zhongping Chen; Kristen M Kelly; J Stuart Nelson Journal: IEEE J Sel Top Quantum Electron Date: 2015-10-26 Impact factor: 4.544
Authors: Igor Snast; Moshe Lapidoth; Ran Kaftory; Adi Nosrati; Emmilia Hodak; Daniel Mimouni; Efrat Solomon-Cohen; Assi Levi Journal: Lasers Med Sci Date: 2021-02-13 Impact factor: 3.161
Authors: Jennifer Channual; Bernard Choi; Kathryn Osann; Daniel Pattanachinda; Justin Lotfi; Kristen M Kelly Journal: Lasers Surg Med Date: 2008-11 Impact factor: 4.025
Authors: M Ingmar van Raath; Ruud Weijer; Gia Hung Nguyen; Bernard Choi; Anton I de Kroon; Michal Heger Journal: J Biomed Nanotechnol Date: 2016-08 Impact factor: 4.099
Authors: Guillermo Aguilar; Bernard Choi; Mans Broekgaarden; Owen Yang; Bruce Yang; Pedram Ghasri; Jennifer K Chen; Rick Bezemer; J Stuart Nelson; Anne Margreet van Drooge; Albert Wolkerstorfer; Kristen M Kelly; Michal Heger Journal: Ann Biomed Eng Date: 2011-10-21 Impact factor: 3.934