Literature DB >> 11952206

Detection of Escherichia coli O157:H7 in 10- and 25-gram ground beef samples with an evanescent-wave biosensor with silica and polystyrene waveguides.

Daniel R Demarco1, Daniel V Lim.   

Abstract

A portable evanescent-wave fiber-optic biosensor was used to detect Escherichia coli O157:H7 in seeded 10- and 25-g ground beef samples. The biosensor works by launching light from a 635-nm laser diode into specially designed optical fiber probes, generating an evanescent field that extends approximately 1,000 nm from the fiber surface. Fluorescent molecules within the evanescent field are excited, and a portion of their emission recouples into the fiber probe. The return path emission is transported by an optical fiber to a photodiode within the biosensor that detects and quantifies the fluorescent signal. A sandwich immunoassay was performed on the fiber probes with cyanine 5 dye-labeled polyclonal anti-E. coli O157:H7 antibodies for generation of the specific fluorescent signal. Biotin-streptavidin interactions were used to attach polyclonal anti-E. coli O157:H7 antibodies to the surface of the fiber probe. A centrifugation method was developed to obtain samples suitable for biosensor analysis from 10- and 25-g ground beef samples. The assay was shown to be sensitive and repeatable. One hundred percent correct identification of positive samples was demonstrated at 9.0 x 10(3) CFU/g for 25-g ground beef samples with silica waveguides and at 5.2 x 10(2) CFU/g for 10-g ground beef samples with polystyrene waveguides. The reaction was highly specific. No false positives were observed for 10-g ground beef samples not spiked with the pathogen. In addition, when samples were spiked with high concentrations of a variety of non-E. coli O157:H7 organisms, no false positives were observed. The method was rapid, with results being obtained within 25 min of sample processing.

Entities:  

Mesh:

Year:  2002        PMID: 11952206     DOI: 10.4315/0362-028x-65.4.596

Source DB:  PubMed          Journal:  J Food Prot        ISSN: 0362-028X            Impact factor:   2.077


  12 in total

Review 1.  Current and developing technologies for monitoring agents of bioterrorism and biowarfare.

Authors:  Daniel V Lim; Joyce M Simpson; Elizabeth A Kearns; Marianne F Kramer
Journal:  Clin Microbiol Rev       Date:  2005-10       Impact factor: 26.132

2.  Nondestructive methods for quality evaluation of livestock products.

Authors:  K Narsaiah; Shyam N Jha
Journal:  J Food Sci Technol       Date:  2011-02-17       Impact factor: 2.701

3.  Optical biosensors for food quality and safety assurance-a review.

Authors:  K Narsaiah; Shyam Narayan Jha; Rishi Bhardwaj; Rajiv Sharma; Ramesh Kumar
Journal:  J Food Sci Technol       Date:  2011-07-06       Impact factor: 2.701

4.  Rapid ultrafiltration concentration and biosensor detection of enterococci from large volumes of Florida recreational water.

Authors:  Stephaney D Leskinen; Daniel V Lim
Journal:  Appl Environ Microbiol       Date:  2008-05-30       Impact factor: 4.792

Review 5.  Biosensor: an emerging safety tool for meat industry.

Authors:  Pradeep Kumar Singh; Gauri Jairath; Satyavir Singh Ahlawat; Ashok Pathera; Prashant Singh
Journal:  J Food Sci Technol       Date:  2015-09-26       Impact factor: 2.701

6.  Borosilicate Glass Fiber-Optic Biosensor for the Detection of Escherichia coli.

Authors:  Michael B Maas; Giles H C Maybery; Willem J Perold; Deon P Neveling; Leon M T Dicks
Journal:  Curr Microbiol       Date:  2017-10-24       Impact factor: 2.188

7.  Detection of low levels of Listeria monocytogenes cells by using a fiber-optic immunosensor.

Authors:  Tao Geng; Mark T Morgan; Arun K Bhunia
Journal:  Appl Environ Microbiol       Date:  2004-10       Impact factor: 4.792

8.  Antimicrobial Resistance in Commensal Escherichia coli Isolated from Pigs and Pork Derived from Farms Either Routinely Using or Not Using In-Feed Antimicrobials.

Authors:  Kittitat Lugsomya; Jitrapa Yindee; Waree Niyomtham; Chanwit Tribuddharat; Padet Tummaruk; David J Hampson; Nuvee Prapasarakul
Journal:  Microb Drug Resist       Date:  2018-09       Impact factor: 3.431

9.  Sensing Escherichia coli O157:H7 via frequency shift through a self-assembled monolayer based QCM immunosensor.

Authors:  Li-jiang Wang; Chun-sheng Wu; Zhao-ying Hu; Yuan-fan Zhang; Rong Li; Ping Wang
Journal:  J Zhejiang Univ Sci B       Date:  2008-02       Impact factor: 3.066

10.  Development of a Cryptosporidium oocyst assay using an automated fiber optic-based biosensor.

Authors:  Marianne F Kramer; Graham Vesey; Natasha L Look; Ben R Herbert; Joyce M Simpson-Stroot; Daniel V Lim
Journal:  J Biol Eng       Date:  2007-10-10       Impact factor: 4.355

View more