In vitro study on the dimensional accuracy of selected materials for monophase elastic impression making.

Andree Piwowarczyk1, Peter Ottl, Alfred Büchler, Hans-Christoph Lauer, Andrea Hoffmann.   

Abstract

PURPOSE: This study evaluated the dimensional accuracy of various impression materials for monophase elastic impression making. To isolate this parameter, a direct measurement of the impressions was made without taking the model material into consideration.
MATERIALS AND METHODS: A total of eight materials were tested; six impression materials were addition-curing silicones, and two were polyether impression materials. All materials were processed according to the manufacturers' instructions. A specially developed precision mold made of stainless steel served as basis for measuring the elastomeric impression materials. Using a stereomicroscope at a temperature of 23.0 +/- 1.0 degrees C and with a precision linear adjustment and lathe, sights were set on the marking points of customized posts. The measurement was performed after the earliest time possible for fabricating the model according to the manufacturer (time 1) and after 90 minutes (time 2). In a one-way analysis of variance, multiple average comparisons of dimensional accuracy were made (P < or = .05) between the impression materials under investigation.
RESULTS: Under the conditions of this study, the impression materials tested demonstrated a very high dimensional accuracy. The arithmetic means of the dimensional changes ranged from -11 to 19 microns for both measuring times.
CONCLUSION: Since as a rule, no significant dimensional changes occurred for the different impression materials between time 1 and time 2, this time interval for fabricating a model can be recommended.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11951807

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  7 in total

1.  Influence of material surface on the scanning error of a powder-free 3D measuring system.

Authors:  Michael Kurz; Thomas Attin; Albert Mehl
Journal:  Clin Oral Investig       Date:  2015-03-07       Impact factor: 3.573

2.  Dimensional Accuracy of Hydrophilic and Hydrophobic VPS Impression Materials Using Different Impression Techniques - An Invitro Study.

Authors:  Sreeramulu Basapogu; Ajai Pilla; Suman Pathipaka
Journal:  J Clin Diagn Res       Date:  2016-02-01

3.  In Vitro Comparative Evaluation of Different Types of Impression Trays and Impression Materials on the Accuracy of Open Tray Implant Impressions: A Pilot Study.

Authors:  Sonam Gupta; Aparna Ichalangod Narayan; Dhanasekar Balakrishnan
Journal:  Int J Dent       Date:  2017-02-27

4.  Accuracy of Digital Impression Taking Using Intraoral Scanner versus the Conventional Technique.

Authors:  Arash Zarbakhsh; Ezatollah Jalalian; Nazanin Samiei; Mohammad Hossein Mahgoli; Hadi Kaseb Ghane
Journal:  Front Dent       Date:  2021-02-10

5.  Accuracy of Conventional and Digital Methods of Obtaining Full-Arch Dental Impression (In Vitro Study).

Authors:  Hassan A Husein; Mhd Luai Morad; Shaza Kanout
Journal:  Cureus       Date:  2022-09-11

6.  Effect of cervical relining of acrylic resin copings on the accuracy of stone dies obtained using a polyether impression material.

Authors:  André Tomazini Gomes de Sá; César Antunes de Freitas; Fátima Cristina de Sá; Wagner José Silva Ursi; Tânia Christina Simões; Márcia Furtado Antunes de Freitas
Journal:  J Appl Oral Sci       Date:  2008 Jan-Feb       Impact factor: 2.698

7.  Can transfer type and implant angulation affect impression accuracy? A 3D in vitro evaluation.

Authors:  Davide Farronato; Pietro Mario Pasini; Veronica Campana; Diego Lops; Lorenzo Azzi; Mattia Manfredini
Journal:  Odontology       Date:  2021-06-01       Impact factor: 2.634

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.