Relevance of antecedent venography in percutaneous vertebroplasty for the treatment of osteoporotic compression fractures.

John R Gaughen1, Mary E Jensen, Patricia A Schweickert, Timothy J Kaufmann, William F Marx, David F Kallmes.   

Abstract

BACKGROUND AND
PURPOSE: Controversy exists regarding the utility of antecedent venography in percutaneous vertebroplasty. Our purpose was to determine whether antecedent venography improves clinical outcomes and/or decreases extravertebral cement extravasation in these procedures.
METHODS: We retrospective reviewed outcomes of consecutive percutaneous vertebroplasty procedures performed at our institution to define two populations, each consisting of 24 patients treated at 42 vertebral levels. Group 1 included patients who underwent antecedent venography, and group 2 included patients treated without venography. Clinical outcomes were assessed with quantitative measurements of pain and mobility. Venograms and postprocedural radiographs were interpreted to evaluate the number of vertebrae with extravertebral cement extravasation, degree of extravasation at each level, and correlation between venography and vertebroplasty.
RESULTS: Pain improved in 19 of 20 group 1 patients, compared with 21 of 22 group 2 patients; mean postoperative pain levels were 1.3 and 1.8, respectively (P =.50), on a scale of 0 (no pain) to 10 (worst pain). All 11 group 1 patients with impaired preoperative mobility reported postoperative improvement, as did all 12 group 2 patients; mean levels of postoperative impaired mobility for groups 1 and 2 were 0.35 and 0.27, respectively (P =.43). Twenty-two of 42 vertebrae treated in group 1 demonstrated extravasation, compared with 28 of 42 in group 2 (P =.266); amounts of extravasation did not differ. Among 22 levels of extravasation in group 1, venograms in 14 showed correlative extravasation.
CONCLUSION: Antecedent venography does not significantly improve the effectiveness or safety of percutaneous vertebroplasty performed by qualified, experienced operators.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11950650      PMCID: PMC7975077     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  10 in total

Review 1.  Percutaneous vertebroplasty: a developing standard of care for vertebral compression fractures.

Authors:  J M Mathis; J D Barr; S M Belkoff; M S Barr; M E Jensen; H Deramond
Journal:  AJNR Am J Neuroradiol       Date:  2001-02       Impact factor: 3.825

2.  Vertebroplasty: clinical experience and follow-up results.

Authors:  J B Martin; B Jean; K Sugiu; D San Millán Ruíz; M Piotin; K Murphy; B Rüfenacht; M Muster; D A Rüfenacht
Journal:  Bone       Date:  1999-08       Impact factor: 4.398

3.  [Percutaneous vertebral surgery. Technics and indications].

Authors:  J Chiras; C Depriester; A Weill; M T Sola-Martinez; H Deramond
Journal:  J Neuroradiol       Date:  1997-06       Impact factor: 3.447

4.  Pulmonary embolism caused by acrylic cement: a rare complication of percutaneous vertebroplasty.

Authors:  B Padovani; O Kasriel; P Brunner; P Peretti-Viton
Journal:  AJNR Am J Neuroradiol       Date:  1999-03       Impact factor: 3.825

Review 5.  Fractures of the osteoporotic spine.

Authors:  L D Cohen
Journal:  Orthop Clin North Am       Date:  1990-01       Impact factor: 2.472

6.  Percutaneous vertebroplasty guided by a combination of CT and fluoroscopy.

Authors:  A Gangi; B A Kastler; J L Dietemann
Journal:  AJNR Am J Neuroradiol       Date:  1994-01       Impact factor: 3.825

7.  Long-term observations of vertebral osteoporotic fractures treated by percutaneous vertebroplasty.

Authors:  F Grados; C Depriester; G Cayrolle; N Hardy; H Deramond; P Fardellone
Journal:  Rheumatology (Oxford)       Date:  2000-12       Impact factor: 7.580

8.  Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: technical aspects.

Authors:  M E Jensen; A J Evans; J M Mathis; D F Kallmes; H J Cloft; J E Dion
Journal:  AJNR Am J Neuroradiol       Date:  1997 Nov-Dec       Impact factor: 3.825

9.  Value of bone scan imaging in predicting pain relief from percutaneous vertebroplasty in osteoporotic vertebral fractures.

Authors:  A S Maynard; M E Jensen; P A Schweickert; W F Marx; J G Short; D F Kallmes
Journal:  AJNR Am J Neuroradiol       Date:  2000 Nov-Dec       Impact factor: 3.825

10.  Spinal metastases: indications for and results of percutaneous injection of acrylic surgical cement.

Authors:  A Weill; J Chiras; J M Simon; M Rose; T Sola-Martinez; E Enkaoua
Journal:  Radiology       Date:  1996-04       Impact factor: 11.105

  10 in total
  31 in total

Review 1.  [Complications of vertebroplasty].

Authors:  M A Rauschmann; D von Stechow; K-D Thomann; D Scale
Journal:  Orthopade       Date:  2004-01       Impact factor: 1.087

2.  Radiation dose to the operator during vertebroplasty: prospective comparison of the use of 1-cc syringes versus an injection device.

Authors:  David F Kallmes; Erwin O; Soma Sinha Roy; Richard G Piccolo; William F Marx; Jae K Lee; Mary E Jensen
Journal:  AJNR Am J Neuroradiol       Date:  2003 Jun-Jul       Impact factor: 3.825

3.  Percutaneous vertebroplasty in the therapy of osteoporotic vertebral compression fractures: a critical review.

Authors:  K Hochmuth; D Proschek; W Schwarz; M Mack; A A Kurth; T J Vogl
Journal:  Eur Radiol       Date:  2006-03-16       Impact factor: 5.315

4.  Cement leakage during vertebroplasty: an underestimated problem?

Authors:  R Schmidt; B Cakir; T Mattes; M Wegener; W Puhl; M Richter
Journal:  Eur Spine J       Date:  2005-02-03       Impact factor: 3.134

5.  Intraspinal leakage of bone cement after vertebroplasty: a report of 3 cases.

Authors:  M M H Teng; H Cheng; D M-T Ho; C-Y Chang
Journal:  AJNR Am J Neuroradiol       Date:  2006-01       Impact factor: 3.825

Review 6.  [Vertebroplasty and kyphoplasty in patients with osteoporotic fractures: secured knowledge and open questions].

Authors:  K Bohndorf; R Fessl
Journal:  Radiologe       Date:  2006-10       Impact factor: 0.635

7.  [Sacroplasty for the treatment of insufficiency fractures of the sacrum].

Authors:  G M Hess
Journal:  Orthopade       Date:  2006-08       Impact factor: 1.087

8.  [Sacroplasty for the treatment of sacral insufficiency fractures].

Authors:  G M Hess
Journal:  Unfallchirurg       Date:  2006-08       Impact factor: 1.000

9.  [Extravertebral cement drainage with occlusion of the extradural venous plexus into the vena cava after vertebrobplasty. Case report and review of the literature].

Authors:  M Prymka; T Pühler; S Hirt; H-W Ulrich
Journal:  Unfallchirurg       Date:  2003-10       Impact factor: 1.000

10.  Balloon kyphoplasty: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2004-12-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.