Literature DB >> 11948740

Simulation-based investigation of partially parallel imaging with a linear array at high accelerations.

James A Bankson1, Steven M Wright.   

Abstract

Partially parallel imaging strategies such as SMASH, SENSE, and PILS rely on the sensitivity distribution of phased array RF coils to reduce MRI imaging time. Using an N-element phased array, these techniques allow maximum accelerations, L, such that L < or = N, with acceleration defined as the factor by which scan time is reduced in comparison to traditional, fully gradient encoded acquisitions. As N increases in modern MRI facilities or using special hardware extensions, its role as the primary limitation in partially parallel imaging will be reduced and other limiting factors will become dominant. Two such factors include available SNR and the variation of sensitivity distributions with imaging depth. Simulations have been conducted to evaluate the impact of slice depth and noise on partially parallel reconstructions for the case of a square linear array of overlapped elements that are parallel to the imaging plane. Results indicate that even when sensitivity distributions are exactly known, the linear surface array can only provide high accelerations over a limited imaging depth due to changing suitability of the sensitivity distributions for partially parallel reconstruction. This work emphasizes the importance of simulations for target-based partially parallel array design. Copyright 2002 Wiley-Liss, Inc.

Mesh:

Year:  2002        PMID: 11948740     DOI: 10.1002/mrm.10113

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

1.  Magnetic resonance temperature imaging validation of a bioheat transfer model for laser-induced thermal therapy.

Authors:  D Fuentes; C Walker; A Elliott; A Shetty; J D Hazle; R J Stafford
Journal:  Int J Hyperthermia       Date:  2011       Impact factor: 3.914

2.  4 T Actively detuneable double-tuned 1H/31P head volume coil and four-channel 31P phased array for human brain spectroscopy.

Authors:  N I Avdievich; H P Hetherington
Journal:  J Magn Reson       Date:  2007-03-03       Impact factor: 2.229

3.  Calculation of radiofrequency electromagnetic fields and their effects in MRI of human subjects.

Authors:  Christopher M Collins; Zhangwei Wang
Journal:  Magn Reson Med       Date:  2011-03-04       Impact factor: 4.668

4.  DeepSENSE: Learning coil sensitivity functions for SENSE reconstruction using deep learning.

Authors:  Xi Peng; Bradley P Sutton; Fan Lam; Zhi-Pei Liang
Journal:  Magn Reson Med       Date:  2021-11-26       Impact factor: 4.668

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.