Literature DB >> 11948728

Detection and elimination of motion artifacts by regeneration of k-space.

M Bydder1, D J Larkman, J V Hajnal.   

Abstract

A method has been developed using techniques from partially parallel imaging (PPI) to detect localized inconsistencies in k-space that are caused by certain types of motion. The inconsistent data are discarded and consistent data regenerated from the remaining data using PPI techniques. The price is a small decrease in signal-to-noise ratio (SNR) and additional postprocessing. An iterative scheme is presented which does not require separately acquired coil sensitivity information for the PPI reconstructions. This method has been found to reduce artifact levels in phantom and in vivo test studies. Copyright 2002 Wiley-Liss, Inc.

Mesh:

Year:  2002        PMID: 11948728     DOI: 10.1002/mrm.10093

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  19 in total

1.  Correction of B 0-induced geometric distortion variations in prospective motion correction for 7T MRI.

Authors:  Uten Yarach; Chaiya Luengviriya; Daniel Stucht; Frank Godenschweger; Peter Schulze; Oliver Speck
Journal:  MAGMA       Date:  2016-02-09       Impact factor: 2.310

Review 2.  Parallel magnetic resonance imaging.

Authors:  Ulrich Katscher; Peter Börnert
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

Review 3.  Motion artifacts in MRI: A complex problem with many partial solutions.

Authors:  Maxim Zaitsev; Julian Maclaren; Michael Herbst
Journal:  J Magn Reson Imaging       Date:  2015-01-28       Impact factor: 4.813

4.  Augmented generalized SENSE reconstruction to correct for rigid body motion.

Authors:  Roland Bammer; Murat Aksoy; Chunlei Liu
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

5.  Reverse retrospective motion correction.

Authors:  Benjamin Zahneisen; Brian Keating; Aditya Singh; Michael Herbst; Thomas Ernst
Journal:  Magn Reson Med       Date:  2015-07-03       Impact factor: 4.668

6.  Correction of gradient nonlinearity artifacts in prospective motion correction for 7T MRI.

Authors:  Uten Yarach; Chaiya Luengviriya; Appu Danishad; Daniel Stucht; Frank Godenschweger; Peter Schulze; Oliver Speck
Journal:  Magn Reson Med       Date:  2014-05-05       Impact factor: 4.668

7.  POCS-enhanced correction of motion artifacts in parallel MRI.

Authors:  Alexey A Samsonov; Julia Velikina; Youngkyoo Jung; Eugene G Kholmovski; Chris R Johnson; Walter F Block
Journal:  Magn Reson Med       Date:  2010-04       Impact factor: 4.668

8.  High-resolution multishot spiral diffusion tensor imaging with inherent correction of motion-induced phase errors.

Authors:  Trong-Kha Truong; Arnaud Guidon
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

9.  SimPACE: generating simulated motion corrupted BOLD data with synthetic-navigated acquisition for the development and evaluation of SLOMOCO: a new, highly effective slicewise motion correction.

Authors:  Erik B Beall; Mark J Lowe
Journal:  Neuroimage       Date:  2014-06-24       Impact factor: 6.556

10.  Rigid-body motion correction with self-navigation MRI.

Authors:  Jason Mendes; Eugene Kholmovski; Dennis L Parker
Journal:  Magn Reson Med       Date:  2009-03       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.