Literature DB >> 11944093

Standardising surface electromyogram recordings for assessment of activity and fatigue in the human upper trapezius muscle.

Dario Farina1, Pascal Madeleine, Thomas Graven-Nielsen, Roberto Merletti, Lars Arendt-Nielsen.   

Abstract

The objectives of this work were to determine optimal surface electromyogram (EMG) electrode locations, and inter-electrode distance (IED), when assessing activity and fatigue in the human upper trapezius muscle. Surface EMG signals were recorded from the upper trapezius muscle of 11 healthy male subjects using a linear array of 16 surface electrodes. Five arm positions were investigated (arms at the side of the body, 45 degrees and 90 degrees flexion, 45 degrees and 90 degrees abduction). Fatiguing (1 kg hand load held for 3 min) and non-fatiguing (no load, 0.5 kg and 1 kg hand load held for 3 s) contractions were made. The variabilities of the average rectified value, root mean square, mean and median power spectral frequency and slope over time of these parameters as functions of electrode location and IED (from 5 mm over a range of 35 mm in steps of 5 mm) were quantitatively evaluated. A criterion for selecting the optimal electrode position was applied. This criterion indicated an optimal location measured from the acromion (38% of the distance from the lateral edge of acromion to the spine of the seventh cervical vertebra) which was statistically the same for all the EMG descriptors, arm positions and IED investigated. Finally, it was found that both EMG variables and indexes of muscle fatigue depended on IED which should thus be properly standardised. On the basis of the sensitivity of the EMG descriptors to electrode location and cross-talk reduction, an IED of 20 mm is suggested when a global analysis of activity in the upper trapezius muscle is made using a single pair of electrodes. This study emphasises that a surface EMG analysis of the upper trapezius muscle, following a proper placement of the electrodes and selection of IED, can give reliable indications of muscle activity and fatigue. Data on the myoelectric manifestations of muscle fatigue of the upper trapezius muscle are provided for the optimal electrode location.

Entities:  

Mesh:

Year:  2002        PMID: 11944093     DOI: 10.1007/s00421-001-0574-0

Source DB:  PubMed          Journal:  Eur J Appl Physiol        ISSN: 1439-6319            Impact factor:   3.078


  39 in total

1.  Single motor unit analysis from spatially filtered surface electromyogram signals. Part 2: conduction velocity estimation.

Authors:  E Schulte; D Farina; G Rau; R Merletti; C Disselhorst-Klug
Journal:  Med Biol Eng Comput       Date:  2003-05       Impact factor: 2.602

2.  Single motor unit analysis from spatially filtered surface electromyogram signals. Part I: spatial selectivity.

Authors:  D Farina; E Schulte; R Merletti; G Rau; C Disselhorst-Klug
Journal:  Med Biol Eng Comput       Date:  2003-05       Impact factor: 2.602

3.  Effects of electrode dislocation on electromyographic activity and relative rest time: effectiveness of compensation by a normalisation procedure.

Authors:  H J Hermens; M M R Vollenbroek-Hutten
Journal:  Med Biol Eng Comput       Date:  2004-07       Impact factor: 2.602

4.  Influence of muscle fibre shortening on estimates of conduction velocity and spectral frequencies from surface electromyographic signals.

Authors:  E Schulte; D Farina; R Merletti; G Rau; C Disselhorst-Klug
Journal:  Med Biol Eng Comput       Date:  2004-07       Impact factor: 2.602

5.  Sixty-four channel wearable acquisition system for long-term surface electromyogram recording with electrode arrays.

Authors:  M Pozzo; A Bottin; R Ferrabone; R Merletti
Journal:  Med Biol Eng Comput       Date:  2004-07       Impact factor: 2.602

6.  Motor unit action potential rate and motor unit action potential shape properties in subjects with work-related chronic pain.

Authors:  Laura A C Kallenberg; Hermie J Hermens
Journal:  Eur J Appl Physiol       Date:  2004-09-29       Impact factor: 3.078

7.  Active biofeedback changes the spatial distribution of upper trapezius muscle activity during computer work.

Authors:  Afshin Samani; Andreas Holtermann; Karen Søgaard; Pascal Madeleine
Journal:  Eur J Appl Physiol       Date:  2010-05-29       Impact factor: 3.078

8.  Electromyographic Evaluation of the Effect of Lined Dentures on Masticatory Muscle Activity in Edentulous Subjects.

Authors:  Abhishek Rastogi; Shitij Srivastava; Abhishek Gaur; Arun Dupare; Shiksha Rastogi; Laxmikant Kamatagi
Journal:  J Clin Diagn Res       Date:  2015-08-01

9.  Single motor unit and spectral surface EMG analysis during low-force, sustained contractions of the upper trapezius muscle.

Authors:  Dario Farina; Daniel Zennaro; Marco Pozzo; Roberto Merletti; Thomas Läubli
Journal:  Eur J Appl Physiol       Date:  2004-12-21       Impact factor: 3.078

10.  Comparison of the electromyographic activity in the upper trapezius and biceps brachii muscle in subjects with muscular disorders: a pilot study.

Authors:  E Schulte; L A C Kallenberg; H Christensen; C Disselhorst-Klug; H J Hermens; G Rau; K Søgaard
Journal:  Eur J Appl Physiol       Date:  2005-02-04       Impact factor: 3.078

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.