Literature DB >> 26436054

Electromyographic Evaluation of the Effect of Lined Dentures on Masticatory Muscle Activity in Edentulous Subjects.

Abhishek Rastogi1, Shitij Srivastava2, Abhishek Gaur3, Arun Dupare4, Shiksha Rastogi5, Laxmikant Kamatagi6.   

Abstract

AIM: The purpose of this study was to examine changes in relative electromyographic (EMG) activities of temporal and masseter muscles after relining the dentures with silicone and acrylic-resin based denture liners.
MATERIALS AND METHODS: Conventional complete dentures were fabricated for 20 edentulous patients. One month after completing adjustments of the dentures, electromyography of the masseter and temporalis muscle during maximum intercuspation was recorded. The dentures were then relined with a silicone denture liner and after an adaptation period of one month, were again subjected for electromyographic evaluation. Further, the dentures were relined with acrylic denture liner and subjected to electromyographic evaluation. Data was analysed using Statistical Package for Social Sciences (SPSS) version 15.0. Intergroup comparisons were done using ANOVA followed by post-hoc assessments using Tukey HSD test.
RESULTS: Mean amplitude and duration with conventional dentures was found to be significantly lower as compared to silicone lined and acrylic lined dentures for all the comparisons. Statistically, no significant difference between silicone lined and acrylic lined dentures was observed for any of the comparisons.
CONCLUSION: Within the limitations of this experimental design, it was concluded that relining significantly increases electromyographic activity of the masseter and temporalis muscles. Thus, resulting in an improved biting force, chewing efficiency and masticatory performance. There were no significant differences between silicone and acrylic based denture liners for both electromyographic variables.

Entities:  

Keywords:  Electromyography; Masseter muscle and temporalis muscle; Silicone and acrylic denture liners

Year:  2015        PMID: 26436054      PMCID: PMC4576648          DOI: 10.7860/JCDR/2015/13186.6359

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  24 in total

1.  Changes in the masticatory function of complete denture wearers after relining the mandibular denture with a soft denture liner.

Authors:  I Hayakawa; S Hirano; Y Takahashi; E S Keh
Journal:  Int J Prosthodont       Date:  2000 May-Jun       Impact factor: 1.681

Review 2.  Measuring chewing ability in randomized controlled trials with edentulous populations wearing implant prostheses.

Authors:  J S Feine; J P Lund
Journal:  J Oral Rehabil       Date:  2006-04       Impact factor: 3.837

3.  Measurement in vivo of masticatory mucosal thickness with 20 MHz B-mode ultrasonic diagnostic equipment.

Authors:  H Uchida; K Kobayashi; M Nagao
Journal:  J Dent Res       Date:  1989-02       Impact factor: 6.116

4.  The influence of occlusion on jaw and neck muscle activity: a surface EMG study in healthy young adults.

Authors:  V F Ferrario; G M Tartaglia; A Galletta; G P Grassi; C Sforza
Journal:  J Oral Rehabil       Date:  2006-05       Impact factor: 3.837

5.  A hydrophilic denture base resin.

Authors:  M J Barsby; M Braden
Journal:  J Dent Res       Date:  1979-06       Impact factor: 6.116

6.  Characterization of the physical properties of resilient denture liners.

Authors:  J A von Fraunhofer; W J Sichina
Journal:  Int J Prosthodont       Date:  1994 Mar-Apr       Impact factor: 1.681

7.  Electromyography of masticatory muscles after denture relining with soft and hard denture liners.

Authors:  Marina X Pisani; Antonio L M Segundo; Vanessa M F Leite; Raphael F de Souza; Marco A M R da Silva; Cláudia H L da Silva
Journal:  J Oral Sci       Date:  2013-09       Impact factor: 1.556

8.  Randomized controlled clinical trial on satisfaction with resilient denture liners among edentulous patients.

Authors:  Suguru Kimoto; Manabu Kitamura; Maria Kodaira; Shirou Yamamoto; Yousuke Ohno; Yasuhiko Kawai; Misao Kawara; Kihei Kobayashi
Journal:  Int J Prosthodont       Date:  2004 Mar-Apr       Impact factor: 1.681

9.  Neuromuscular coordination of masticatory muscles in subjects with two types of implant-supported prostheses.

Authors:  Virgilio F Ferrario; Gianluca M Tartaglia; Michele Maglione; Massimo Simion; Chiarella Sforza
Journal:  Clin Oral Implants Res       Date:  2004-04       Impact factor: 5.977

10.  Clinical application of a soft denture liner: a case report.

Authors:  R T Williamson
Journal:  Quintessence Int       Date:  1995-06       Impact factor: 1.677

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.