Transcutaneous functional electrical stimulator "Compex Motion".

Thierry Keller1, Milos R Popovic, Ion P I Pappas, Pierre-Yves Müller.   

Abstract

Research groups in the field of functional electrical stimulation (FES) are often confronted with the fact that existing and commercially available FES stimulators do not provide sufficient flexibility and cannot be used to perform different FES tasks. The lack of flexibility of the commercial systems until now forced various FES research teams to develop their own stimulators. This paper presents a newly developed firmware and graphical programming software for the commercial Compex 2 stimulator which enhances the versatility and capabilities of the stimulator from a medical and therapeutic device to a neuroprosthesis and research tool. The new stimulator, called Compex Motion, can now be used to develop various custom-made neuroprostheses, neurological assessment devices, muscle exercise systems, and experimental setups for physiological studies. It can be programmed to generate any arbitrary stimulation sequence that can be controlled or regulated by various external sensors, sensory systems, or laboratory equipment. By interconnecting two or more Compex Motion stimulators, the number of stimulation channels can be increased to multiples of four channels, 8, 12, 16, 20, and so forth. The stimulation sequences and the control strategies are programmed and stored on exchangeable credit card-sized memory chip cards. The stimulator has four biphasic current-regulated stimulation channels and two general purpose analog input channels that can be configured to measure the output voltage of a variety of sensors such as goniometers, inclinometers, gyroscopes, or electromyographic (EMG) sensors. For real-time EMG control of the stimulation patterns, an EMG processing algorithm with software stimulation artifact blanking was implemented. The Compex Motion stimulator is manufactured by the Swiss company Compex SA and is currently undergoing clinical trials.

Entities:  

Mesh:

Year:  2002        PMID: 11940017     DOI: 10.1046/j.1525-1594.2002.06934.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  19 in total

1.  The effects of wide pulse neuromuscular electrical stimulation on elbow flexion torque in individuals with chronic hemiparetic stroke.

Authors:  J M Clair-Auger; D F Collins; J P A Dewald
Journal:  Clin Neurophysiol       Date:  2012-05-22       Impact factor: 3.708

2.  Insula-specific responses induced by dental pain. A proton magnetic resonance spectroscopy study.

Authors:  A Gutzeit; D Meier; M L Meier; C von Weymarn; D A Ettlin; N Graf; J M Froehlich; C A Binkert; M Brügger
Journal:  Eur Radiol       Date:  2010-10-02       Impact factor: 5.315

3.  Cortical and subcortical correlates of functional electrical stimulation of wrist extensor and flexor muscles revealed by fMRI.

Authors:  Armin Blickenstorfer; Raimund Kleiser; Thierry Keller; Birgit Keisker; Martin Meyer; Robert Riener; Spyros Kollias
Journal:  Hum Brain Mapp       Date:  2009-03       Impact factor: 5.038

4.  Overcoming abnormal joint torque patterns in paretic upper extremities using triceps stimulation.

Authors:  Thierry Keller; Michael D Ellis; Julius P A Dewald
Journal:  Artif Organs       Date:  2005-03       Impact factor: 3.094

5.  Impaired scaling of responses to vestibular stimulation in incomplete SCI.

Authors:  S Wydenkeller; M Liechti; R Müller; A Curt
Journal:  Exp Brain Res       Date:  2006-09-28       Impact factor: 1.972

6.  Differential NMR spectroscopy reactions of anterior/posterior and right/left insular subdivisions due to acute dental pain.

Authors:  Andreas Gutzeit; Dieter Meier; Johannes M Froehlich; Klaus Hergan; Sebastian Kos; Constantin V Weymarn; Kai Lutz; Dominik Ettlin; Christoph A Binkert; Jochen Mutschler; Sabine Sartoretti-Schefer; Mike Brügger
Journal:  Eur Radiol       Date:  2012-09-12       Impact factor: 5.315

7.  Tracking local anesthetic effects using a novel perceptual reference approach.

Authors:  Dominik A Ettlin; Nenad Lukic; Jetmir Abazi; Sonja Widmayer; Michael L Meier
Journal:  J Neurophysiol       Date:  2016-01-20       Impact factor: 2.714

8.  Interactive visuo-motor therapy system for stroke rehabilitation.

Authors:  Kynan Eng; Ewa Siekierka; Pawel Pyk; Edith Chevrier; Yves Hauser; Monica Cameirao; Lisa Holper; Karin Hägni; Lukas Zimmerli; Armin Duff; Corina Schuster; Claudio Bassetti; Paul Verschure; Daniel Kiper
Journal:  Med Biol Eng Comput       Date:  2007-08-09       Impact factor: 2.602

9.  A model for transcutaneous current stimulation: simulations and experiments.

Authors:  Andreas Kuhn; Thierry Keller; Marc Lawrence; Manfred Morari
Journal:  Med Biol Eng Comput       Date:  2008-11-13       Impact factor: 2.602

10.  Brain-computer interface-triggered functional electrical stimulation therapy for rehabilitation of reaching and grasping after spinal cord injury: a feasibility study.

Authors:  Lazar I Jovanovic; Naaz Kapadia; Vera Zivanovic; Hope Jervis Rademeyer; Mohammad Alavinia; Colleen McGillivray; Sukhvinder Kalsi-Ryan; Milos R Popovic; Cesar Marquez-Chin
Journal:  Spinal Cord Ser Cases       Date:  2021-03-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.