Literature DB >> 11932818

Stereotactic biopsies guided by an optical navigation system: technique and clinical experience.

P Grunert1, J Espinosa, C Busert, M Günthner, R Filippi, S Farag, N Hopf.   

Abstract

Frame-based stereotactic biopsies are time-consuming procedures making necessary head fixation in a ring, explicit coordinate calculation and setting of the parameters. Frameless systems make many of these intermediate steps unnecessary, impose less mechanical restrictions regarding access to the lesions, and with slight modifications can be used to perform stereotactic biopsies. A special adaptation designed to fix the holder and the biopsy instrument is described. The neuronavigation optical tracking system of Radionics was used. CT scans were performed with 6 skin markers. Calibration was performed after head fixation in the Mayfield clamp. Mean calibration error was 2.19 +/- 0.81 mm. The light-emitting diode holder of the pointer was fixed into 2 Leila arms and moved under visual control based on CT images. The target point was selected, Leila arms fixed and a burr hole performed. The cannula was introduced to the target, being fitted with a depth stop in a length identical to that of the pointer on the screen. If necessary a second trajectory was easily selected. 49 patients underwent a frameless stereotactic biopsy. All targets except seven were superficial or in the white matter. In selected cases the biopsies were taken from deep-seated lesions. A histological diagnosis was obtained in 100 % of the cases. Four cases deteriorated postoperatively, two of these related to intratumoral bleeding. Navigation is a simple and effective method to perform biopsies of superficial and relatively large lesions. Frame-based procedures are restricted to brainstem tumors and lesions less than 1.5 cm in diameter.

Entities:  

Mesh:

Year:  2002        PMID: 11932818     DOI: 10.1055/s-2002-23576

Source DB:  PubMed          Journal:  Minim Invasive Neurosurg        ISSN: 0946-7211


  7 in total

1.  Real-time MR-guided brain biopsy using 1.0-T open MRI scanner.

Authors:  Xiangmeng He; Ming Liu; Chao Liu; Jing Fang; Yujun Xu; Ligang Wang; Jianfeng Xiang; Roberto Blanco Sequeiros; Chengli Li
Journal:  Eur Radiol       Date:  2018-06-12       Impact factor: 5.315

2.  Preclinical evaluation of a prototype freehand drill video guidance system for orthopedic surgery.

Authors:  Niral Sheth; Prasad Vagdargi; Alejandro Sisniega; Ali Uneri; Gregory Osgood; Jeffrey H Siewerdsen
Journal:  J Med Imaging (Bellingham)       Date:  2022-08-26

3.  Endoscope-assisted microsurgery for tumors of the septum pellucidum: surgical considerations and benefits of the method in the treatment of four serial cases.

Authors:  M Fratzoglou; A R Leite dos Santos; I Gawish; A Perneczky
Journal:  Neurosurg Rev       Date:  2004-05-12       Impact factor: 3.042

Review 4.  Frame-based stereotaxy in a frameless era: current capabilities, relative role, and the positive- and negative predictive values of blood through the needle.

Authors:  Christopher M Owen; Mark E Linskey
Journal:  J Neurooncol       Date:  2009-05-09       Impact factor: 4.130

Review 5.  Diffusion-weighted imaging in head and neck cancers.

Authors:  Sanjeev Chawla; Sungheon Kim; Sumei Wang; Harish Poptani
Journal:  Future Oncol       Date:  2009-09       Impact factor: 3.404

6.  Drill-mounted video guidance for orthopaedic trauma surgery.

Authors:  Prasad Vagdargi; Niral Sheth; Alejandro Sisniega; Ali Uneri; Tharindu De Silva; Greg M Osgood; Jeffrey H Siewerdsen
Journal:  J Med Imaging (Bellingham)       Date:  2021-02-12

7.  Feasability of a Frameless Brain Biopsy System for Companion Animals Using Cone-Beam CT-Based Automated Registration.

Authors:  Felix Meneses; Arianna Maiolini; Franck Forterre; Anna Oevermann; Daniela Schweizer-Gorgas
Journal:  Front Vet Sci       Date:  2022-02-09
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.