Assessment of distortion in a three-dimensional rotational angiography system.

R R Bridcut1, R J Winder, A Workman, P Flynn.   

Abstract

The purpose of this project was to determine the degree of geometrical distortion in a three-dimensional (3D) image volume generated by a digital fluorography system with rotational image acquisition capabilities. 3D imaging is a valuable adjunct in neuroangiography for visualization and measurement of cerebral aneurysms and for determination of the optimum projection for intervention. To enable spatially accurate 3D reconstruction the system must correct for geometrical distortion in the image intensifier television system as well as for deviations in gantry motion. 3D volumes were reconstructed from 100 X-ray projections acquired over a 180 degrees arc over a period of 8 s. A phantom was constructed to assess geometrical distortion in the three dimensions. The phantom consisted of 1 mm diameter ball bearings embedded in Perspex in a cubic lattice configuration. The ball bearings were placed at 20 mm intervals over a 140 mm cubic volume. Distortion was assessed by taking measurements between points of known separation and using a differential distortion measurement. The maximum error in the 3D location of objects was found to be 1.4 mm, while the differential distortion was found to range from -1.0% to +2.3%. The 3D images were found to have negligible visual distortion, enabling subjective assessments to be made with confidence to aid intervention.

Entities:  

Mesh:

Year:  2002        PMID: 11932221     DOI: 10.1259/bjr.75.891.750266

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  2 in total

1.  Use of cone-beam computed tomography angiography in planning for gamma knife radiosurgery for arteriovenous malformations: a case series and early report.

Authors:  Mina G Safain; Jason P Rahal; Ami Raval; Mark J Rivard; John E Mignano; Julian K Wu; Adel M Malek
Journal:  Neurosurgery       Date:  2014-06       Impact factor: 4.654

2.  Selective and super-selective C-arm based cone beam CT angiography (CBCTA) with DynaCT for CyberKnife radiosurgery planning of intracranial arteriovenous malformations (AVMs).

Authors:  Oliver Edwin Holmes; Janos Szanto; Vered Tsehmaister Abitbul; Taleb Al Mansoori; Hanan Al-Qahtani; John Sinclair; Daniela Iancu; Shawn Malone
Journal:  J Radiosurg SBRT       Date:  2018
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.