Literature DB >> 11927686

Interactive effect of chondroitin sulphate C and hyaluronan on fluid movement across rabbit synovium.

S Sabaratnam1, P J Coleman, E Badrick, R M Mason, J R Levick.   

Abstract

The polysaccharide hyaluronan (HA) conserves synovial fluid by keeping outflow low and almost constant over a wide pressure range ('buffering'), but only at concentrations associated with polymer domain overlap. We therefore tested whether polymer interactions can cause buffering, using HA-chondroitin sulphate C (CSC) mixtures. Also, since it has been found that capillary filtration is insensitive to the Starling force interstitial osmotic pressure in frog mesenteries, this was assessed in synovium. Hyaluronan at non-buffering concentrations (0.50-0.75 mg ml(-1)) and/or 25 mg ml(-1) CSC (osmotic pressure 68 cmH(2)O) was infused into knees of anaesthetised rabbits in vivo. Viscometry and chromatography confirmed that HA interacts with CSC. Pressure (P(j)) versus trans-synovial flow (;Q(s)) relations were measured.;Q(s) was outwards for HA alone (1.2 +/- 0.9 microl min(-1) at 3 cmH(2)O, mean +/- S.E.M.; n = 6). CSC diffused into synovium and changed;Q(s) to filtration at low P(j) (-4.1 microl min(-1), 3 cmH(2)O, n = 5, P < 0.02, t test). Filtration ceased upon circulatory arrest (n = 3). At higher P(j), 0.75 mg ml(-1) HA plus CSC buffered;Q(s) to approximately 3 microl min(-1) over a wide range of P(j), with an outflow increase of only 0.04 +/- 0.02 microl min(-1) cmH(2)O(-1) (n = 4). With HA or CSC alone, buffering was absent (slopes 0.57 +/- 0.04 microl min(-1) cmH(2)O(-1) (n = 4) and 0.86 +/- 0.05 microl min(-1) cmH(2)O(-1) (n = 5), respectively). Therefore, polymer interactions can cause outflow buffering in joints. Also, interstitial osmotic pressure promoted filtration in fenestrated synovial capillaries, so the results for frog mesentery capillaries cannot be generalised. The difference is attributed to differences in pore ultrastructure.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11927686      PMCID: PMC2290215          DOI: 10.1113/jphysiol.2001.013468

Source DB:  PubMed          Journal:  J Physiol        ISSN: 0022-3751            Impact factor:   5.182


  37 in total

1.  A new view of Starling's hypothesis at the microstructural level.

Authors:  X Hu; S Weinbaum
Journal:  Microvasc Res       Date:  1999-11       Impact factor: 3.514

2.  The partition of solutes between buffer solutions and solutions containing hyaluronic acid.

Authors:  A G OGSTON; C F PHELPS
Journal:  Biochem J       Date:  1961-04       Impact factor: 3.857

3.  Evidence for simultaneous bidirectional fluid flux across synovial lining in knee joints of anaesthetized rabbits.

Authors:  J N McDonald; J R Levick
Journal:  Exp Physiol       Date:  1992-05       Impact factor: 2.969

4.  Hydrodynamic properties of connective-tissue polysaccharides.

Authors:  W D Comper; O Zamparo
Journal:  Biochem J       Date:  1990-08-01       Impact factor: 3.857

5.  Relation between trans-synovial flow and plasma osmotic pressure, with an estimation of the albumin reflection coefficient in the rabbit knee.

Authors:  A D Knight; J R Levick; J N McDonald
Journal:  Q J Exp Physiol       Date:  1988-01

6.  Glycosaminoglycan concentration in synovium and other tissues of rabbit knee in relation to synovial hydraulic resistance.

Authors:  F M Price; J R Levick; R M Mason
Journal:  J Physiol       Date:  1996-09-15       Impact factor: 5.182

7.  An analysis of the interaction between interstitial plasma protein, interstitial flow, and fenestral filtration and its application to synovium.

Authors:  J R Levick
Journal:  Microvasc Res       Date:  1994-01       Impact factor: 3.514

8.  The interaction of convection and diffusion in the transport of 131I-albumin within the media of the rabbit thoracic aorta.

Authors:  A Tedgui; M J Lever
Journal:  Circ Res       Date:  1985-12       Impact factor: 17.367

9.  The composition and physicochemical properties of hyaluronic acids prepared from ox synovial fluid and from a case of mesothelioma.

Authors:  B N Preston; M Davies; A G Ogston
Journal:  Biochem J       Date:  1965-08       Impact factor: 3.857

10.  Effect of intra-articular hyaluronan on pressure-flow relation across synovium in anaesthetized rabbits.

Authors:  J N McDonald; J R Levick
Journal:  J Physiol       Date:  1995-05-15       Impact factor: 5.182

View more
  8 in total

1.  Characterization of engineered cartilage constructs using multiexponential T₂ relaxation analysis and support vector regression.

Authors:  Onyi N Irrechukwu; David A Reiter; Ping-Chang Lin; Remigio A Roque; Kenneth W Fishbein; Richard G Spencer
Journal:  Tissue Eng Part C Methods       Date:  2012-02-21       Impact factor: 3.056

Review 2.  Elasticity in extracellular matrix 'shape modules' of tendon, cartilage, etc. A sliding proteoglycan-filament model.

Authors:  J E Scott
Journal:  J Physiol       Date:  2003-08-15       Impact factor: 5.182

3.  Oncotic pressures opposing filtration across non-fenestrated rat microvessels.

Authors:  R H Adamson; J F Lenz; X Zhang; G N Adamson; S Weinbaum; F E Curry
Journal:  J Physiol       Date:  2004-04-08       Impact factor: 5.182

4.  Size selectivity of hyaluronan molecular sieving by extracellular matrix in rabbit synovial joints.

Authors:  S Sabaratnam; V Arunan; P J Coleman; R M Mason; J R Levick
Journal:  J Physiol       Date:  2005-06-16       Impact factor: 5.182

Review 5.  Viscosupplementation with hyaluronic acid in the treatment for cartilage lesions: a review of current evidence and future directions.

Authors:  Travis E Clegg; David Caborn; Cyril Mauffrey
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-01-28

6.  Increased hyaluronan expression at distinct time points in acute lymphedema.

Authors:  Melissa A Roberts; Uziel Mendez; Ryan J Gilbert; Alexander P Keim; Jeremy Goldman
Journal:  Lymphat Res Biol       Date:  2012-09       Impact factor: 2.589

7.  Prediction of cartilage compressive modulus using multiexponential analysis of T(2) relaxation data and support vector regression.

Authors:  Onyi N Irrechukwu; Sarah Von Thaer; Eliot H Frank; Ping-Chang Lin; David A Reiter; Alan J Grodzinsky; Richard G Spencer
Journal:  NMR Biomed       Date:  2014-02-12       Impact factor: 4.044

8.  Vascular refilling coefficient is not a good marker of whole-body capillary hydraulic conductivity in hemodialysis patients: insights from a simulation study.

Authors:  Leszek Pstras; Jacek Waniewski; Bengt Lindholm
Journal:  Sci Rep       Date:  2022-09-10       Impact factor: 4.996

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.