Literature DB >> 11924975

In-channel electrochemical detection for microchip capillary electrophoresis using an electrically isolated potentiostat.

R Scott Martin1, Kenneth L Ratzlaff, Bryan H Huynh, Susan M Lunte.   

Abstract

A new electrode configuration for microchip capillary electrophoresis (CE) with electrochemical (EC) detection is described. This approach makes it possible to place the working electrode directly in the separation channel. The "in-channel" EC detection was accomplished without the use of a decoupler through the utilization of a specially designed, electrically isolated potentiostat. The effect of the working electrode position on the separation performance (in terms of plate height and peak skew) of poly(dimethylsiloxane)-based microchip CEEC devices was evaluated by comparing the more commonly used end-channel configuration with this new in-channel approach. Using catechol as the test analyte, it was found that in-channel EC detection decreased the total plate height by a factor of 4.6 and lowered the peak skew by a factor of 1.3. A similar trend was observed for the small, inorganic ion nitrite. Furthermore, a fluorescent and electrochemically active amino acid derivative was used to directly compare the separation performance of in-channel EC detection to that of a widely used laser-induced fluorescence (LIF) detection scheme. In this case, it was found that the plate height and peak skew for both detection schemes were essentially equal, and the separation performance of in-channel EC detection is comparable to LIF detection.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11924975     DOI: 10.1021/ac011087p

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  14 in total

Review 1.  Bioanalytical profile of the L-arginine/nitric oxide pathway and its evaluation by capillary electrophoresis.

Authors:  Dmitri Y Boudko
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2007-02-15       Impact factor: 3.205

2.  On-column electrochemical detection for microchip capillary electrophoresis.

Authors:  Damon M Osbourn; Craig E Lunte
Journal:  Anal Chem       Date:  2003-06-01       Impact factor: 6.986

3.  Evaluation of in-channel amperometric detection using a dual-channel microchip electrophoresis device and a two-electrode potentiostat for reverse polarity separations.

Authors:  Diogenes Meneses; Dulan B Gunasekara; Pann Pichetsurnthorn; José A F da Silva; Fabiane C de Abreu; Susan M Lunte
Journal:  Electrophoresis       Date:  2014-11-14       Impact factor: 3.535

4.  Use of a Carbon-ink Microelectrode Array for Signal Enhancement in Microchip Electrophoresis with Electrochemical Detection.

Authors:  Laura C Mecker; Laura A Filla; R Scott Martin
Journal:  Electroanalysis       Date:  2010-10-01       Impact factor: 3.223

5.  Integration of microchip electrophoresis with electrochemical detection using an epoxy-based molding method to embed multiple electrode materials.

Authors:  Alicia S Johnson; Asmira Selimovic; R Scott Martin
Journal:  Electrophoresis       Date:  2011-10-31       Impact factor: 3.535

6.  Microchip electrophoresis with amperometric detection for the study of the generation of nitric oxide by NONOate salts.

Authors:  Dulan B Gunasekara; Matthew K Hulvey; Susan M Lunte; José Alberto Fracassi da Silva
Journal:  Anal Bioanal Chem       Date:  2012-03-14       Impact factor: 4.142

7.  In-channel amperometric detection for microchip electrophoresis using a wireless isolated potentiostat.

Authors:  Dulan B Gunasekara; Matthew K Hulvey; Susan M Lunte
Journal:  Electrophoresis       Date:  2011-03-16       Impact factor: 3.535

8.  Integration of serpentine channels for microchip electrophoresis with a palladium decoupler and electrochemical detection.

Authors:  Amanda L Bowen; R Scott Martin
Journal:  Electrophoresis       Date:  2009-10       Impact factor: 3.535

9.  Amperometric detection in microchip electrophoresis devices: effect of electrode material and alignment on analytical performance.

Authors:  David J Fischer; Matthew K Hulvey; Anne R Regel; Susan M Lunte
Journal:  Electrophoresis       Date:  2009-10       Impact factor: 3.535

10.  Comparison of the analytical performance of electrophoresis microchannels fabricated in PDMS, glass, and polyester-toner.

Authors:  Wendell Karlos Tomazelli Coltro; Susan M Lunte; Emanuel Carrilho
Journal:  Electrophoresis       Date:  2008-12       Impact factor: 3.535

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.