Literature DB >> 11922506

Comparison of atrial septal defect closure using amplatzer septal occluder with surgery.

K Durongpisitkul1, J Soongswang, D Laohaprasitiporn, A Nana, S Sriyoschati, S Ponvilawan, T Subtaweesin, C Kangkagate.   

Abstract

Our study reports the results of a comparison of closure of atrial septal defect (ASD) surgically with transcatheter closure using the Amplatzer septal occluder. Patients having an ASD and a surgical closure or transcatheter closure between January 1999 and July 2000 were selected. There were 103 patients who had ASD. All 64 patients in group 1 (surgery) had a successful operation, with only 2 patients with a mild residual shunt. There were 39 patients enrolled for transcatheter closure of the ASD (group 2). Four patients were excluded initially. The median age for group 1 was 25 years (range 2.3-64 years) compared to 11.7 years (range 2-69 years) in group 2 (p = 0.035). In group 1, the mean ASD diameter measured was 28.4 +/- 10.2 mm compared to 23.4 +/- 5.7 mm in group 2 (p = 0.003). In 29 patients, devices were deployed with sizes from 10 mm to 30 mm (median 24 mm). Three patients were excluded because a larger device (>30 mm) was not available and devices were not successfully deployed in another 3 patients. One patient had a device embolized into the right ventricle (surgical removal and closure of the ASD). Complications occurred in 13 patients in group 1 and 4 patients in group 2. Complete occlusion occurred in 27 of 28 group 2 patients (96.4%) during the follow-up period (10.2 +/- 5.4 months). The Amplatzer septal occluder is a new device for closure of different-sized ASDs. The intermediate-term follow-up demonstrated excellent closure results. The benefit for each patient was demonstrated in less morbidity and less time spent in the hospital.

Entities:  

Mesh:

Year:  2002        PMID: 11922506     DOI: 10.1007/s00246-001-0010-6

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  11 in total

1.  Comparison of the Occlutech ® Figulla ® septal occluder and Amplatzer ® septal occluder for atrial septal defect device closure.

Authors:  Supaporn Roymanee; Worakan Promphan; Nakharin Tonklang; Kanjarut Wongwaitaweewong
Journal:  Pediatr Cardiol       Date:  2015-01-30       Impact factor: 1.655

2.  Recent Experience and Follow-Up After Surgical Closure of Secundum Atrial Septal Defect in 120 Children.

Authors:  Geoffroy de Beco; Natasha Mambour; Christophe Vô; Laetitia Vanhoutte; Stéphane Moniotte; Alain Poncelet; Thierry Sluysmans
Journal:  Pediatr Cardiol       Date:  2018-05-22       Impact factor: 1.655

3.  Closure of atrial septal defects in children: surgery versus Amplatzer device implantation.

Authors:  Jacek Bialkowski; Blandyna Karwot; Malgorzata Szkutnik; Pawel Banaszak; Jacek Kusa; Janusz Skalski
Journal:  Tex Heart Inst J       Date:  2004

4.  Predictors of successful transcatheter closure of atrial septal defect by cardiac magnetic resonance imaging.

Authors:  K Durongpisitkul; N L Tang; J Soongswang; D Laohaprasitiporn; A Nanal
Journal:  Pediatr Cardiol       Date:  2003-12-15       Impact factor: 1.655

Review 5.  Transcatheter closure of secundum atrial septal defect.

Authors:  Hideto Shimpo; Reina Hojo; Maeshiro Ryo; Takeshi Konuma; Hironori Tempaku
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-06-18

6.  Comprehensive evaluation of atrial septal defects in individuals undergoing percutaneous repair by 64-detector row computed tomography.

Authors:  Christopher L Gade; Geoffrey Bergman; Srihari Naidu; Jonathan W Weinsaft; Tracy Q Callister; James K Min
Journal:  Int J Cardiovasc Imaging       Date:  2006-09-23       Impact factor: 2.316

7.  Comparison of the response of the right ventricle with endovascular occlusion and surgical closure in adults with atrial septal defect one year after intervention.

Authors:  Niloufar Samiei; Fariba Bayat; Masoud Moradi; Mozhgan Parsaei; Seyedeh Zahra Ojaghi Haghighi; Ahmad Mohebbi; Negar Hamzepour; Fereidoon Noohi
Journal:  Clin Med Insights Cardiol       Date:  2010-12-20

8.  Assessment of right atrial and right ventricular size in children after percutaneous closure of secundum atrial septal defect with Amplatzer septal occluder.

Authors:  Beata Kucinska; Bożena Werner; Maria Wróblewska-Kałużewska
Journal:  Arch Med Sci       Date:  2010-09-07       Impact factor: 3.318

9.  Transcatheter closure of atrial septal defects in children, middle-aged adults, and older adults: failure rates, early complications; and balloon sizing effects.

Authors:  Chodchanok Vijarnsorn; Kritvikrom Durongpisitkul; Prakul Chanthong; Paweena Chungsomprasong; Jarupim Soongswang; Duangmanee Loahaprasitiporn; Apichart Nana
Journal:  Cardiol Res Pract       Date:  2012-06-19       Impact factor: 1.866

10.  Cost-effectiveness of procedures for treatment of ostium secundum atrial septal defects occlusion comparing conventional surgery and septal percutaneous implant.

Authors:  Márcia Gisele Santos da Costa; Marisa da Silva Santos; Flávia Mori Sarti; Kátia Marie Simões e Senna; Bernardo Rangel Tura; Marcelo Goulart Correia; Marcelo Correia Goulart
Journal:  PLoS One       Date:  2014-10-10       Impact factor: 3.240

View more