Evaluating a visual field screening test for glaucoma: how the choice of the gold standard affects the validity of the test.

N J Ellish1, E J Higginbotham.   

Abstract

OBJECTIVE: To examine the effects of the gold standard on sensitivity, specificity, and area under the ROC curve when determining the validity of a screening test.
METHODS: Fifty-eight people were recruited from a Veterans' Administration eye clinic. Screening included testing with the 26-point oculokinetic perimeter (OKP). We used different gold standards to categorize patients as positive or negative for glaucoma. The glaucoma hemifield test (GHT) and corrected pattern standard deviation (CPSD) from the Humphrey visual field analyzer (HVF) were used as objective gold standards. Ophthalmologist review of the HVF, using two different methods for classifying visual field defects, was also used as a gold standard.
RESULTS: Using the review of the HVF that included mild, moderate, or severe defects, the area under the ROC curve was not significantly different from 50%. However, for all the other gold standards, the area under the ROC curve was significantly different from 50%.
CONCLUSIONS: In determining the ability of the OKP to differentiate between glaucoma and normal subjects, the choice of a gold standard led to different conclusions about its usefulness as a screening test for glaucoma. Furthermore, sensitivity and specificity varied widely depending on which gold standard was used, and what cutoff point was used for the OKP. Although clinician review of the HVF may be used when specific criteria are given to define visual field defects, using objective measures from the HVF is easier and will allow for better comparisons between studies.

Entities:  

Mesh:

Year:  2001        PMID: 11922383     DOI: 10.1080/09286586.2001.11644258

Source DB:  PubMed          Journal:  Ophthalmic Epidemiol        ISSN: 0928-6586            Impact factor:   1.648


  2 in total

Review 1.  Screening for primary open-angle glaucoma in the primary care setting: an update for the US preventive services task force.

Authors:  Craig Fleming; Evelyn P Whitlock; Tracy Beil; Barbara Smit; Russell P Harris
Journal:  Ann Fam Med       Date:  2005 Mar-Apr       Impact factor: 5.166

2.  Glaucoma detection with damato multifixation campimetry online.

Authors:  A S Olsen; M Alberti; L Serup; M la Cour; B Damato; M Kolko
Journal:  Eye (Lond)       Date:  2016-03-18       Impact factor: 3.775

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.