Literature DB >> 11922376

Perfusion of the femoral head during surgical dislocation of the hip. Monitoring by laser Doppler flowmetry.

H P Nötzli1, K A Siebenrock, A Hempfing, L E Ramseier, R Ganz.   

Abstract

We used laser Doppler flowmetry (LDF) with a high energy (20 mW) laser to measure perfusion of the femoral head intraoperatively in 32 hips. The surgical procedure was joint debridement requiring dislocation or subluxation of the hip. The laser probe was placed within the anterosuperior quadrant of the femoral head. Blood flow was monitored in specific positions of the hip before and after dislocation or subluxation. With the femoral head reduced, external rotation, both in extension and flexion, caused a reduction of blood flow. During subluxation or dislocation, it was impaired when the posterosuperior femoral neck was allowed to rest on the posterior acetabular rim. A pulsatile signal returned when the hip was reduced, or was taken out of extreme positions when dislocated. After the final reduction, the signal amplitudes were first slightly lower (12%) compared with the initial value but tended to be restored to the initial levels within 30 minutes. Most of the changes in the signal can be explained by compromise of the extraosseous branches of the medial femoral circumflex artery and are reversible. Our study shows that LDF provides proof for the clinical observation that perfusion of the femoral head is maintained after dislocation if specific surgical precautions are followed.

Entities:  

Mesh:

Year:  2002        PMID: 11922376     DOI: 10.1302/0301-620x.84b2.12146

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  45 in total

1.  Audit-induced change reduces complications of the Ganz trochanteric flip approach.

Authors:  P M Guyver; A Cattell; R P Reddy; C Edwards; D Williams; S M Dixon; M R Norton; E D Fern
Journal:  Ann R Coll Surg Engl       Date:  2010-07-02       Impact factor: 1.891

2.  [Femoroacetabular impingement. A common cause of hip complaints leading to arthrosis].

Authors:  M Leunig; R Ganz
Journal:  Unfallchirurg       Date:  2005-01       Impact factor: 1.000

3.  Treatment of anterior femoroacetabular impingement with combined hip arthroscopy and limited anterior decompression.

Authors:  John C Clohisy; J Thomas McClure
Journal:  Iowa Orthop J       Date:  2005

Review 4.  [Femoroacetabular impingement: trigger for the development of coxarthrosis].

Authors:  M Leunig; M Beck; C Dora; R Ganz
Journal:  Orthopade       Date:  2006-01       Impact factor: 1.087

5.  Does surgical approach influence component positioning with Birmingham Hip Resurfacing?

Authors:  G J C Myers; D Morgan; C W McBryde; K O'Dwyer
Journal:  Int Orthop       Date:  2007-10-30       Impact factor: 3.075

6.  The influence of surgical approach on outcome in Birmingham hip resurfacing.

Authors:  Callum W McBryde; Matthew P Revell; Andrew M Thomas; Ronan B Treacy; Paul B Pynsent
Journal:  Clin Orthop Relat Res       Date:  2008-01-26       Impact factor: 4.176

7.  Role of the extraosseus blood supply in osteoarthritic femoral heads?

Authors:  Ralf Schoeniger; Norman Espinosa; Rafael J Sierra; Michael Leunig; Reinhold Ganz
Journal:  Clin Orthop Relat Res       Date:  2009-04-21       Impact factor: 4.176

Review 8.  [Surgical dislocation of the hip for the treatment of femoroacetabular impingement. Technique and results].

Authors:  M Beck; S F Fucentese; L Staub; K Siebenrock
Journal:  Orthopade       Date:  2009-05       Impact factor: 1.087

9.  Performance assessment of an opto-fluidic phantom mimicking porcine liver parenchyma.

Authors:  Tony J Akl; Travis J King; Ruiqi Long; Michael J McShane; M Nance Ericson; Mark A Wilson; Gerard L Coté
Journal:  J Biomed Opt       Date:  2012-07       Impact factor: 3.170

10.  Capital realignment for moderate and severe SCFE using a modified Dunn procedure.

Authors:  Kai Ziebarth; Christoph Zilkens; Samantha Spencer; Michael Leunig; Reinhold Ganz; Young-Jo Kim
Journal:  Clin Orthop Relat Res       Date:  2009-01-14       Impact factor: 4.176