Abstract

BACKGROUND: The accuracy of fluorodeoxyglucose positron emission tomography (FDG-PET; dual-head camera with attenuation correction) and Ga-67 scintigraphy was compared to identify disease sites in patients with Hodgkin disease (HD) and intermediate and high-grade non-Hodgkin lymphoma (NHL) at initial diagnosis or clinical recurrence.
METHODS: Fifty-one contemporaneous FDG-PET and Ga-67 scintigraphies were performed on patients with NHL (35 intermediate grade, 3 high grade) or HD (13 patients). Sites of disease were correlated on a site-by-site basis on FDG-PET and Ga-67 images. Tumor-to-background (T/B) ratios were obtained for both techniques. Discordant FDG-PET and Ga-67 findings were correlated with computed tomography findings or clinical evaluation including repeat FDG-PET scans obtained after therapy.
RESULTS: Fluorodeoxyglucose positron emission tomography was positive at all 158 sites in 51 patients compared with 113 sites in 41 positive studies with Ga-67 scintigraphy (single positron emission computed tomography [SPECT] and/or planar images). In 44 patients who had complete Ga-67 SPECT data on all tumor sites, FDG-PET was positive at 126 sites and Ga-67 SPECT was positive at 81 sites. Ga-67 SPECT failed to demonstrate disease at 45 sites (35.7%). In 10 of 44 patients, Ga-67 SPECT completely failed to detect any disease at 22 of 45 sites (17.5%) and partially identified disease sites at 23 of 45 sites (18.2%) in 11 patients regardless of the tumor site and histology. In these patients, the lesions measured between 0.6 and 14.0 cm by CT. Fluorodeoxyglucose positron emission tomography revealed higher stage disease in 13 patients compared with Ga-67 imaging. Tumor-to-background ratios were statistically different between the two techniques with higher ratios obtained with FDG-PET (P < 0.0001).
CONCLUSIONS: In imaging aggressive lymphoma and HD before therapy, FDG-PET has significantly higher site and patient sensitivity than Ga-67 scintigraphy (100% vs. 71.5% and 100% vs. 80.3%, respectively). The change in disease stage by FDG-PET may result in a change in therapy strategy. Copyright 2002 American Cancer Society. DOI 10.1002/cncr.10336

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11920454

Source DB:  PubMed          Journal:  Cancer        ISSN: 0008-543X            Impact factor:   6.860


  20 in total

Review 1.  Impact of technology on the utilisation of positron emission tomography in lymphoma: current and future perspectives.

Authors:  D Visvikis; P J Ell
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-05-13       Impact factor: 9.236

Review 2.  PET in lymphoma.

Authors:  Conor D Collins
Journal:  Cancer Imaging       Date:  2006-10-31       Impact factor: 3.909

3.  Lymphomatous involvement of gastrointestinal tract: evaluation by positron emission tomography with (18)F-fluorodeoxyglucose.

Authors:  Sith Phongkitkarun; Vithya Varavithya; Toshiki Kazama; Silvana C Faria; Martha V Mar; Donald A Podoloff; Homer A Macapinlac
Journal:  World J Gastroenterol       Date:  2005-12-14       Impact factor: 5.742

Review 4.  Lymphoma: current status of clinical and preclinical imaging with radiolabeled antibodies.

Authors:  Christopher G England; Lixin Rui; Weibo Cai
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-11-14       Impact factor: 9.236

Review 5.  Gallium-67 scintigraphy: a cornerstone in functional imaging of lymphoma.

Authors:  Einat Even-Sapir; Ora Israel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-03-18       Impact factor: 9.236

6.  Thyroid uptake of 67Ga-citrate is associated with thyroid autoimmunity and hypothyroidism in patients with sarcoidosis.

Authors:  Alessandro Antonelli; Piera Fazzi; Poupak Fallahi; Silvia Martina Ferrari; Mariano Grosso; Giuseppe Boni; Ele Ferrannini; Giuliano Mariani
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-09-09       Impact factor: 9.236

Review 7.  Role and cost effectiveness of PET/CT in management of patients with cancer.

Authors:  Muhammad Wasif Saif; Ifigenia Tzannou; Nektaria Makrilia; Kostas Syrigos
Journal:  Yale J Biol Med       Date:  2010-06

Review 8.  FDG-PET imaging in hematological malignancies.

Authors:  L Valls; C Badve; S Avril; K Herrmann; P Faulhaber; J O'Donnell; N Avril
Journal:  Blood Rev       Date:  2016-04-16       Impact factor: 8.250

9.  Role of PET/CT in malignant pediatric lymphoma.

Authors:  Raef Riad; Walid Omar; Magdy Kotb; Magdy Hafez; Iman Sidhom; Manal Zamzam; Iman Zaky; Hussein Abdel-Dayem
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-09-15       Impact factor: 9.236

10.  Use of 18F-fluorodeoxyglucose positron emission tomography in patients with rare head and neck cancers.

Authors:  Jong-Lyel Roh; Byoung Jae Moon; Jae Seung Kim; Jeong Hyun Lee; Kyung-Ja Cho; Seung-Ho Choi; Soon Yuhl Nam; Bong-Jae Lee; Sang Yoon Kim
Journal:  Clin Exp Otorhinolaryngol       Date:  2008-06-20       Impact factor: 3.372

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.