Literature DB >> 11916269

Quantification of sirolimus by liquid chromatography-tandem mass spectrometry using on-line solid-phase extraction.

Michael Vogeser1, Claudia Fleischer, Bruno Meiser, Jan Groetzner, Ute Spöhrer, Dietrich Seidel.   

Abstract

Quantification of the new immunosuppressant sirolimus (syn. rapamycin; Rapamune) in whole blood by chromatography is essential for its clinical use since no immunoassay is available although monitoring is mandatory. Here we report on a rapid and convenient liquid chromatography (LC-tandem mass spectrometry method and describe our practical experience with its routine use. Whole blood samples were hemolyzed and deproteinized using an equal volume (150 microl) of a mixture of methanol/zinc sulfate solution containing the internal standard desmethoxy-rapamycin. After centrifugation, the clear supernatants were submitted to an on-line solid-phase extraction procedure using the polymeric Waters Oasis HLB material, with elution of the extracts onto the analytical column in the back-flush mode by column switching. For analytical chromatography a RP-C18 column was used with 90/10 methanol/2 mM ammonium acetate as the mobile phase. A 1:10 split was used for the transfer to the mass spectrometer, a Micromass Quattro LC-tandem mass spectrometry system equipped with a Z-spray source and used in the positive electrospray ionization mode. The following transitions were recorded: sirolimus, 931>864 m/z, and desmethoxy-rapamycin (I.S.), 901>834 m/z. The analytical running time was 5 min, including on-line extraction. The method has a linear calibration curve (r>0.99; range 1.6-50 microg/l) and is rugged and precise with monthly CVs <7% at a sirolimus concentration of 13.1 microg/l in routine use; the instrumentation proved to be reliable and required minimal maintenance. Clin Chem

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11916269     DOI: 10.1515/CCLM.2002.008

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  4 in total

1.  Accuracy evaluation of automated electrochemiluminescence immunoassay for everolimus and sirolimus compared to liquid chromatography-tandem mass spectrometry.

Authors:  Eun Jin Lee; Hyun-Ki Kim; Sunyoung Ahn; Woochang Lee; Hyun Soo Kim; Sail Chun; Won-Ki Min
Journal:  J Clin Lab Anal       Date:  2019-06-14       Impact factor: 2.352

2.  Development and Validation of a Bioanalytical LC-MS/MS Method for Simultaneous Determination of Sirolimus in Porcine Whole Blood and Lung Tissue and Pharmacokinetic Application with Coronary Stents.

Authors:  Thi-Thao-Linh Nguyen; Van-An Duong; Dang-Khoa Vo; Jeongae Jo; Han-Joo Maeng
Journal:  Molecules       Date:  2021-01-15       Impact factor: 4.411

3.  Comparison of LC-MS/MS and EMIT methods for the precise determination of blood sirolimus in children with vascular anomalies.

Authors:  Yue-Tao Zhao; Hao-Ran Dai; Yue Li; Yuan-Yuan Zhang; Hong-Li Guo; Xuan-Sheng Ding; Ya-Hui Hu; Feng Chen
Journal:  Front Pharmacol       Date:  2022-09-06       Impact factor: 5.988

4.  A new approach for the determination of immunosuppressive drugs using HPLC-MS/MS and Cs+ adducts.

Authors:  Patricia Kaiser; Theodorus Akerboom; William Graham Wood; Hans Reinauer
Journal:  Ger Med Sci       Date:  2006-01-18
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.