Halogen versus high-intensity light-curing of uncoated and pre-coated brackets: a shear bond strength study.

M F Sfondrini1, V Cacciafesta, C Klersy.   

Abstract

AIM: To evaluate the shear bond strengths of adhesive pre-coated brackets (APC) and conventional uncoated brackets (Victory) cured with two different light-curing units: a conventional halogen light (Visilux 2) and a micro-xenon light (Aurys).
SETTING: Ex vivo study
MATERIALS AND METHODS: Sixty freshly extracted bovine permanent mandibular incisors were randomly assigned to one of four groups, each group consisting of 15 specimens. Two groups (one for each type of bracket) were exposed to the halogen light for 20 seconds and used as controls. The remaining two groups were cured with the micro-xenon light for 2 seconds. After 24 hours, all samples were tested in a shear mode on an Instron Machine. Analysis was by two-way ANOVA with Scheffé's test for comparisons, Kaplan-Meier survival estimates, and Cox model. The Chi-square (chi(2)) test was used to determine significant differences in the ARI scores.
RESULTS: The mean shear bond strength of the uncoated brackets cured with Visilux 2 was significantly higher than those of all the other groups tested. Both groups cured with Visilux 2 produced significantly higher mean shear bond strengths than those of the corresponding groups cured with Aurys. No statistically significant differences were found between the two groups cured with Aurys.
CONCLUSIONS: Compared to halogen light-curing, the micro-xenon light enables the clinician to reduce significantly the curing time of both APC and uncoated brackets, and although significantly lower, their shear bond strengths may be clinically acceptable.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11907309     DOI: 10.1093/ortho/29.1.45

Source DB:  PubMed          Journal:  J Orthod        ISSN: 1465-3125


  6 in total

1.  Effect of Dental Chair Light on Enamel Bonding of Orthodontic Brackets Using Light Cure Based Adhesive System: An In-Vitro Study.

Authors:  Anil Tiwari; Tarulatha Shyagali; Sarvraj Kohli; Rishi Joshi; Abhishek Gupta; Rana Tiwari
Journal:  Acta Inform Med       Date:  2016-11-01

2.  Prevention of white spot lesions around orthodontic brackets using organoselenium-containing antimicrobial enamel surface sealant.

Authors:  Bennett T Amaechi; Brandon McGarrell; Minh N Luong; Linda O Okoye; Peter T Gakunga
Journal:  Heliyon       Date:  2021-03-12

3.  Shear bond strength of a bracket-bonding system cured with a light-emitting diode or halogen-based light-curing unit at various polymerization times.

Authors:  Sanjay Prasad Gupta; Basanta Kumar Shrestha
Journal:  Clin Cosmet Investig Dent       Date:  2018-04-10

4.  Clinical bond failure rates of adhesive precoated self-ligating brackets using a self-etching primer.

Authors:  Mete Ozer; Mehmet Bayram; Cagri Dincyurek; Fuat Tokalak
Journal:  Angle Orthod       Date:  2013-07-02       Impact factor: 2.079

5.  Shear bond strength of precoated orthodontic brackets: an in vivo study.

Authors:  Ali H Hassan
Journal:  Clin Cosmet Investig Dent       Date:  2010-06-15

6.  Comparison of shear bond strength of orthodontic brackets bonded with halogen and plasma arc light curing.

Authors:  Mohammad Hossein Toodehzaeim; Alireza Danesh Kazemi; Hossein Agha Aghili; Kazem Barzegar; Taranom Fallahtafti
Journal:  Dent Res J (Isfahan)       Date:  2012-05
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.