False alarm rates of three third-generation pulse oximeters in PACU, ICU and IABP patients.

Norbert O Lutter1, Sabine Urankar, Steffi Kroeber.   

Abstract

The objective of this clinical study was to determine alarm rates--in particular the frequency of false positive alarms--of three third-generation pulse oximeters in the postanesthesia care unit (PACU), the intensive care unit (ICU), and in patients with an intra-aortic balloon pump (IABP): Nellcor Symphony N-3000, a Masimo IVY 2000, and Agilent Viridia CMS 2000. All alarms were classified into technical/physiological and false/correct. 235 consecutive ASA physical status I-IV patients after surgery were included into the study. In the PACU false positive alarms were rare: CMS n = 60, N-3000 n = 60, Masimo n = 87. Bland-Altman testing discovered only negligible differences of alarm rates and dropout times. Out of a total of 728 alarms 67.3% were classified as false positive in ICU-patients: 97 alarms by CMS, 176 by N-3000 and 218 by Masimo SET. If IABP was present, CMS indicated a significant smaller number of false positive alarms (n = 35, 7.2%) when compared to Masimo SET (n = 188, 38.9%) and N-3000 (n = 229, 47.4%), consecutively the majority of false positive alarms (76.2%) can be rated as a result of the interference of IABP. Unless IABP (and to a considerably smaller extent cardiac arrhythmia) is present the pulse oximeters do not differ significantly regarding sensitivity and specificity.

Entities:  

Mesh:

Year:  2002        PMID: 11900042

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  4 in total

1.  Pulse oximetry.

Authors:  Amal Jubran
Journal:  Intensive Care Med       Date:  2004-07-24       Impact factor: 17.440

2.  [Reliability of home monitoring with event-recording compared with polysomnography in infants].

Authors:  Sabine de Nardi; Ekkehart Paditz; Thomas Erler; Andreas Gruntzke
Journal:  Wien Klin Wochenschr       Date:  2003-07-15       Impact factor: 1.704

3.  Parental preference and perspectives on continuous pulse oximetry in infants and children with bronchiolitis.

Authors:  Mohamed A Hendaus; Suzan Nassar; Bassil A Leghrouz; Ahmed H Alhammadi; Mohammed Alamri
Journal:  Patient Prefer Adherence       Date:  2018-04-03       Impact factor: 2.711

4.  Pulse oximetry in bronchiolitis: is it needed?

Authors:  Mohamed A Hendaus; Fatima A Jomha; Ahmed H Alhammadi
Journal:  Ther Clin Risk Manag       Date:  2015-10-12       Impact factor: 2.423

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.