Literature DB >> 11898061

[Determination of the axis after totalendoprosthesis of the knee: functional X-ray photography as golden standard].

M R Langenbach1, J Dohle, H Zirngibl.   

Abstract

AIM: To examine the question of which X-ray photography technique should be given preference after implantation of total endoprosthesis of the knee.
METHOD: 20 patients (age 74.1; 12 men, 8 women) with total endoprosthesis of the knee (Type Sigma, PFC, Johnson and Johnson) because of primary athrosis. Postoperatively X-ray photographs of the whole leg in standing and 40 x 20 a. p. in a flat position were taken. The angles of the axis were determined and the information analysed.
RESULTS: By means of X-ray photography of the whole leg we obtained the following angles: caput-collum-diaphyse 125 +/- 4.3 degrees, femur/basis of the knee 83.2 +/- 2.6 degrees, mechanical femur axis/basis of the knee 89.3 +/- 1.8 degrees, tibia/basis of the talus 89.2 +/- 2.2 degrees. With the 40 x 20 a. p. X-ray photographs we determined the following angles: femur/basis of the knee 82.3 +/- 3.1 degrees, basis of knee/tibia 92.2 +/- 3,6 degrees. Correlating the angles of femur/basis of the knee and basis of the knee/tibia were relations of 0.42 (p < 0.05) and 0.27 (p < 0.05).
CONCLUSION: For gaining information about the axis of the leg under functional conditions, one should give preference to X-ray photography of the whole leg.

Entities:  

Mesh:

Year:  2002        PMID: 11898061     DOI: 10.1055/s-2002-22088

Source DB:  PubMed          Journal:  Z Orthop Ihre Grenzgeb        ISSN: 0044-3220


  5 in total

1.  Agreement between radiological and computer navigation measurement of lower limb alignment.

Authors:  Julian Dexel; Stephan Kirschner; Klaus-Peter Günther; Jörg Lützner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-07-06       Impact factor: 4.342

2.  Inconsistencies between navigation data and radiographs in total knee arthroplasty are system-dependent and affect coronal alignment.

Authors:  Alberto Carli; Ahmed Aoude; Avishai Reuven; Bogdan Matache; John Antoniou; David J Zukor
Journal:  Can J Surg       Date:  2014-10       Impact factor: 2.089

3.  Patient-specific computed tomography based instrumentation in total knee arthroplasty: a prospective randomized controlled study.

Authors:  Andrzej Kotela; Ireneusz Kotela
Journal:  Int Orthop       Date:  2014-06-28       Impact factor: 3.075

4.  Determining knee joint alignment using digital photographs.

Authors:  Holger Schmitt; Hannes Kappel; Michael T Moser; Eloy Cardenas-Montemayor; Karoly Engelleiter; Benita Kuni; Michael Clarius
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-06-13       Impact factor: 4.342

5.  Measurement of lower limb alignment: there are within-person differences between weight-bearing and non-weight-bearing measurement modalities.

Authors:  Daphne A L Schoenmakers; Peter Z Feczko; Bert Boonen; Martijn G M Schotanus; Nanne P Kort; Pieter J Emans
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-07-18       Impact factor: 4.342

  5 in total