Literature DB >> 11888817

Intracardiac echocardiography.

C J Bruce1, P A Friedman.   

Abstract

This article describes currently available intracardiac ultrasound (ICE) technology contrasting it with intravascular ultrasound (IVUS), highlighting their differences. General and specific clinical applications, limitations and future developments of ICE are addressed. ICE is possible because lower frequency transducers (in contrast to higher frequency IVUS devices) have been miniaturized and mounted onto catheters capable of percutaneous insertion into the heart. Since the recent availability of a steerable, 5.5--10MHz phased-array catheter with full Doppler capability, these lower frequency transducers are not only capable of enhanced penetration, permitting high-resolution two-dimensional (2D) imaging but can also provide haemodynamic data. ICE facilitates electrophysiologic procedures by guiding trans-septal catheterization, enabling endocardial anatomy visualization, ensuring ablation electrode/tissue contact and promptly diagnosing procedural complications. Promising non-electrophysiologic applications include guidance of percutaneous closure of septal defects, percutaneous mitral balloon valvuloplasty and complex cardiac biopsy. Current limitations include monoplanar imaging and narrow field of view. Expanded diagnostic techniques such as tissue Doppler, multiplane, three dimensional (3D) and multimodality imaging represent future refinements. ICE is now a clinical tool. With the introduction of the newest phased-array transducer, with full Doppler capability, ICE has the potential to play an important role in diagnostic and therapeutic interventional procedures. Further refinement and miniaturization hold the key to primary operator controlled, integrated ultrasound-guided interventional devices.

Entities:  

Mesh:

Year:  2001        PMID: 11888817     DOI: 10.1053/euje.2001.0128

Source DB:  PubMed          Journal:  Eur J Echocardiogr        ISSN: 1532-2114


  3 in total

1.  Beat to beat 3-dimensional intracardiac echocardiography: theoretical approach and practical experiences.

Authors:  Daniel Stapf; Andreas Franke; Marcus Schreckenberg; Georg Schummers; Karl Mischke; Nikolaus Marx; Patrick Schauerte; Christian Knackstedt
Journal:  Int J Cardiovasc Imaging       Date:  2012-10-14       Impact factor: 2.357

2.  Safety of mapping in the sinus of valsalva region under intracardiac echocardiography guidance without angiography.

Authors:  Mike Al Asmar; Mayssam Houssari; Kinan Carlos El-Tallawi; Toufic Feghali; Marwan Refaat; Maurice Khoury; Bernard Abi-Saleh
Journal:  Indian Pacing Electrophysiol J       Date:  2021-02-08

Review 3.  Piezoelectric micromachined ultrasound transducer (PMUT) arrays for integrated sensing, actuation and imaging.

Authors:  Yongqiang Qiu; James V Gigliotti; Margeaux Wallace; Flavio Griggio; Christine E M Demore; Sandy Cochran; Susan Trolier-McKinstry
Journal:  Sensors (Basel)       Date:  2015-04-03       Impact factor: 3.576

  3 in total