Control of nosocomial Legionnaires' disease by keeping the circulating hot water temperature above 55 degrees C: experience from a 10-year surveillance programme in a district general hospital.

J Darelid1, S Löfgren, B-E Malmvall.   

Abstract

After a nosocomial outbreak of Legionnaires' disease in a 450-bed district general hospital in 1991, the circulating hot water temperature was kept above 55 degrees C as the sole control measure. From 1991 to 2000, all cases of nosocomial pneumonia were clinically monitored and tested for Legionella pneumophila serogroup 1 by serology or urinary antigen detection. Water samples from peripheral tap sites were cultured for Legionella spp. twice a year. An infection with L. pneumophila serogroup 1 was diagnosed in four out of 366 (1.1%) patients treated for nosocomial pneumonia, representing one case per 26,000 admissions. All patients were cured without complications. L. pneumophila serogroup 1 was isolated in 30 of 251 (12%) cultured hospital water samples during the monitoring period. We conclude that control of nosocomial Legionnaires' disease in a primary referral hospital is possible by keeping the circulating hospital hot water temperature above 55 degrees C, together with careful clinical surveillance. Complete eradication of Legionella spp. from the hot water system does not seem necessary. Copyright 2002 The Hospital Infection Society.

Entities:  

Mesh:

Year:  2002        PMID: 11886198     DOI: 10.1053/jhin.2002.1185

Source DB:  PubMed          Journal:  J Hosp Infect        ISSN: 0195-6701            Impact factor:   3.926


  18 in total

Review 1.  Amoebae as training grounds for intracellular bacterial pathogens.

Authors:  Maëlle Molmeret; Matthias Horn; Michael Wagner; Marina Santic; Yousef Abu Kwaik
Journal:  Appl Environ Microbiol       Date:  2005-01       Impact factor: 4.792

2.  Microbial and physicochemical parameters associated with Legionella contamination in hot water recirculation systems.

Authors:  Alejandra Serrano-Suárez; Jordi Dellundé; Humbert Salvadó; Sílvia Cervero-Aragó; Javier Méndez; Oriol Canals; Silvia Blanco; Antoni Arcas; Rosa Araujo
Journal:  Environ Sci Pollut Res Int       Date:  2013-02-23       Impact factor: 4.223

3.  Control of Legionella Contamination and Risk of Corrosion in Hospital Water Networks following Various Disinfection Procedures.

Authors:  Isabella Marchesi; Greta Ferranti; Antonella Mansi; Anna M Marcelloni; Anna R Proietto; Navneet Saini; Paola Borella; Annalisa Bargellini
Journal:  Appl Environ Microbiol       Date:  2016-05-02       Impact factor: 4.792

Review 4.  Tenets of a holistic approach to drinking water-associated pathogen research, management, and communication.

Authors:  Caitlin Proctor; Emily Garner; Kerry A Hamilton; Nicholas J Ashbolt; Lindsay J Caverly; Joseph O Falkinham; Charles N Haas; Michele Prevost; D Rebecca Prevots; Amy Pruden; Lutgarde Raskin; Janet Stout; Sarah-Jane Haig
Journal:  Water Res       Date:  2021-12-22       Impact factor: 11.236

5.  Ten Questions Concerning the Aerosolization and Transmission of Legionella in the Built Environment.

Authors:  Aaron J Prussin; David Otto Schwake; Linsey C Marr
Journal:  Build Environ       Date:  2017-06-13       Impact factor: 6.456

Review 6.  Epidemiology and Ecology of Opportunistic Premise Plumbing Pathogens: Legionella pneumophila, Mycobacterium avium, and Pseudomonas aeruginosa.

Authors:  Joseph O Falkinham; Elizabeth D Hilborn; Matthew J Arduino; Amy Pruden; Marc A Edwards
Journal:  Environ Health Perspect       Date:  2015-03-20       Impact factor: 9.031

7.  Convective Mixing in Distal Pipes Exacerbates Legionella pneumophila Growth in Hot Water Plumbing.

Authors:  William J Rhoads; Amy Pruden; Marc A Edwards
Journal:  Pathogens       Date:  2016-03-12

8.  Water heater temperature set point and water use patterns influence Legionella pneumophila and associated microorganisms at the tap.

Authors:  William J Rhoads; Pan Ji; Amy Pruden; Marc A Edwards
Journal:  Microbiome       Date:  2015-12-01       Impact factor: 14.650

9.  Necessity and effect of combating Legionella pneumophila in municipal shower systems.

Authors:  Ragnhild Wiik; Anne Vatland Krøvel
Journal:  PLoS One       Date:  2014-12-09       Impact factor: 3.240

10.  Combination of Heat Shock and Enhanced Thermal Regime to Control the Growth of a Persistent Legionella pneumophila Strain.

Authors:  Emilie Bédard; Inès Boppe; Serge Kouamé; Philippe Martin; Linda Pinsonneault; Louis Valiquette; Jules Racine; Michèle Prévost
Journal:  Pathogens       Date:  2016-04-15