Literature DB >> 11883661

Protein separation and surfactant control of electroosmotic flow in poly(dimethylsiloxane)-coated capillaries and microchips.

M Youssouf Badal1, Margaret Wong, Nghia Chiem, Hossein Salimi-Moosavi, D Jed Harrison.   

Abstract

A thermally pyrolyzed poly(dimethylsiloxane) (PDMS) coating intended to prevent surface adsorption during capillary electrophoretic (CE) [Science 222 (1983) 266] separation of proteins, and to provide a substrate for surfactant adsorption for electroosmotic mobility control was prepared and evaluated. Coating fused-silica capillaries or glass microchip CE devices with a 1% solution of 100 cSt silicone oil in CH2Cl2, followed by forced N2 drying and thermal curing at 400 degrees C for 30 min produced a cross-linked PDMS layer. Addition of 0.01 to 0.02% Brij 35 to a 0.020 M phosphate buffer gave separations of lysozyme, cytochrome c, RNase, and fluorescein-labeled goat anti-human IgG Fab fragment. Respective plates/m typically obtained at 20 kV (740 V cm(-1)) were 2, 1.5, 1.25, and 9.4-10(5). In 50 mM ionic strength phosphate, 0.01% Brij 35 running buffer, the electroosmotic flow observed was about 25% of that in a bare capillary, and showed no pH dependence between pH 6.3-8.2. Addition of sodium dodecylsulfate (SDS) or cetyltrimethylammonium bromide (CTAB) to this running buffer allowed ready control of electroosmotic mobility, mu(eo). Concentrations of SDS between 0.005 to 0.1% resulted in mu(eo) ranging from 3 to 5 x 10(-4) cm2 V(-1) s(-1). Addition of 1 to 2.3 x 10(-4)% (2.7-6.3 microM) CTAB caused flow reversal. CTAB concentrations between 3.5 x 10(-4) and 0.05% (0.0014-1.37 mM) allowed control of mu(eo) between -1 x 10(-4) and -5.0 x 10(-4) cm2 V(-1) s(-1). For both surfactants the added presence of 0.01% Brij 35 provided slowly varying changes in mu(eo) with charged surfactant concentration.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11883661     DOI: 10.1016/s0021-9673(01)01601-6

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  11 in total

1.  Microfluidics: Exploiting elephants in the room.

Authors:  Robert C R Wootton; Andrew J Demello
Journal:  Nature       Date:  2010-04-08       Impact factor: 49.962

2.  Integrated hybrid polystyrene-polydimethylsiloxane device for monitoring cellular release with microchip electrophoresis and electrochemical detection.

Authors:  Alicia S Johnson; Benjamin T Mehl; R Scott Martin
Journal:  Anal Methods       Date:  2015-02-07       Impact factor: 2.896

3.  Simplified microchip electrophoresis for rapid separation of urine proteins.

Authors:  Hongwei Song; Huimin Wang; Saoqing Ju; Qinghui Jin; Chunping Jia; Hui Cong
Journal:  J Clin Lab Anal       Date:  2014-01-06       Impact factor: 2.352

4.  Material-selective separation of mixed microparticles via insulator-based dielectrophoresis.

Authors:  L Weirauch; M Lorenz; N Hill; B H Lapizco-Encinas; M Baune; G R Pesch; J Thöming
Journal:  Biomicrofluidics       Date:  2019-11-15       Impact factor: 2.800

5.  Dielectrophoretic mobility determination in DC insulator-based dielectrophoresis.

Authors:  Noah G Weiss; Paul V Jones; Prasun Mahanti; Kang P Chen; Thomas J Taylor; Mark A Hayes
Journal:  Electrophoresis       Date:  2011-08-08       Impact factor: 3.535

6.  Electrophoretic separations in poly(dimethylsiloxane) microchips using mixtures of ionic, nonionic and zwitterionic surfactants.

Authors:  Qian Guan; Scott D Noblitt; Charles S Henry
Journal:  Electrophoresis       Date:  2012-09       Impact factor: 3.535

7.  Electrophoretic separations in poly(dimethylsiloxane) microchips using a mixture of ionic and zwitterionic surfactants.

Authors:  Qian Guan; Scott D Noblitt; Charles S Henry
Journal:  Electrophoresis       Date:  2012-01       Impact factor: 3.535

8.  Polymer microchip CE of proteins either off- or on-chip labeled with chameleon dye for simplified analysis.

Authors:  Ming Yu; Hsiang-Yu Wang; Adam T Woolley
Journal:  Electrophoresis       Date:  2009-12       Impact factor: 3.535

9.  Isolation of target DNA using synergistic magnetic bead transport and electrokinetic flow.

Authors:  Lindsay Schneider; Francis Cui; Anubhav Tripathi
Journal:  Biomicrofluidics       Date:  2021-03-17       Impact factor: 2.800

10.  Fabrication of 3D Fingerprint Phantoms via Unconventional Polycarbonate Molding.

Authors:  Clayton W Schultz; Jessica X H Wong; Hua-Zhong Yu
Journal:  Sci Rep       Date:  2018-06-25       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.