Literature DB >> 23019105

Electrophoretic separations in poly(dimethylsiloxane) microchips using mixtures of ionic, nonionic and zwitterionic surfactants.

Qian Guan1, Scott D Noblitt, Charles S Henry.   

Abstract

The use of surfactant mixtures to affect both EOF and separation selectivity in electrophoresis with PDMS substrates is reported, and capacitively coupled contactless conductivity detection is introduced for EOF measurement on PDMS microchips. First, the EOF was measured for two nonionic surfactants (Tween 20 and Triton X-100), mixed ionic/nonionic surfactant systems (SDS/Tween 20 and SDS/Triton X-100), and finally for the first time, mixed zwitterionic/nonionic surfactant systems (TDAPS/Tween 20 and TDAPS/Triton X-100). EOF for the nonionic surfactants decreased with increasing surfactant concentration. The addition of SDS or TDAPS to a nonionic surfactant increased EOF. After establishing the EOF behavior, the separation of model catecholamines was explored to show the impact on separations. Similar analyte resolution with greater peak heights was achieved with mixed surfactant systems containing Tween 20 and TDAPS relative to the single surfactant system. Finally, the detection of catecholamine release from PC12 cells by stimulation with 80 mM K(+) was performed to demonstrate the usefulness of mixed surfactant systems to provide resolution of biological compounds in complex samples.
© 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23019105      PMCID: PMC3804416          DOI: 10.1002/elps.201200255

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  62 in total

Review 1.  Recent developments in amperometric detection for microchip capillary electrophoresis.

Authors:  Walter R Vandaveer; Stephanie A Pasas; R Scott Martin; Susan M Lunte
Journal:  Electrophoresis       Date:  2002-11       Impact factor: 3.535

Review 2.  Micro total analysis systems. 2. Analytical standard operations and applications.

Authors:  Pierre-Alain Auroux; Dimitri Iossifidis; Darwin R Reyes; Andreas Manz
Journal:  Anal Chem       Date:  2002-06-15       Impact factor: 6.986

Review 3.  Zeta potential of microfluidic substrates: 1. Theory, experimental techniques, and effects on separations.

Authors:  Brian J Kirby; Ernest F Hasselbrink
Journal:  Electrophoresis       Date:  2004-01       Impact factor: 3.535

Review 4.  Surface treatment and characterization: perspectives to electrophoresis and lab-on-chips.

Authors:  Antoine Pallandre; Bertrand de Lambert; Rafaële Attia; Alain M Jonas; Jean-Louis Viovy
Journal:  Electrophoresis       Date:  2006-02       Impact factor: 3.535

5.  High-sensitivity microchip electrophoresis determination of inorganic anions and oxalate in atmospheric aerosols with adjustable selectivity and conductivity detection.

Authors:  Scott D Noblitt; Florian M Schwandner; Susanne V Hering; Jeffrey L Collett; Charles S Henry
Journal:  J Chromatogr A       Date:  2009-01-06       Impact factor: 4.759

6.  Users' guides to the medical literature. XII. How to use articles about health-related quality of life. Evidence-Based Medicine Working Group.

Authors:  G H Guyatt; C D Naylor; E Juniper; D K Heyland; R Jaeschke; D J Cook
Journal:  JAMA       Date:  1997-04-16       Impact factor: 56.272

7.  Isotopic separation of [(14)n]- and [(15)n]aniline by capillary electrophoresis using surfactant- controlled reversed electroosmotic flow.

Authors:  K K Yeung; C A Lucy
Journal:  Anal Chem       Date:  1998-08-01       Impact factor: 6.986

8.  Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane).

Authors:  D C Duffy; J C McDonald; O J Schueller; G M Whitesides
Journal:  Anal Chem       Date:  1998-12-01       Impact factor: 6.986

9.  Dynamic coating using polyelectrolyte multilayers for chemical control of electroosmotic flow in capillary electrophoresis microchips.

Authors:  Y Liu; J C Fanguy; J M Bledsoe; C S Henry
Journal:  Anal Chem       Date:  2000-12-15       Impact factor: 6.986

Review 10.  Zeta potential of microfluidic substrates: 2. Data for polymers.

Authors:  Brian J Kirby; Ernest F Hasselbrink
Journal:  Electrophoresis       Date:  2004-01       Impact factor: 3.535

View more
  3 in total

1.  Integrated hybrid polystyrene-polydimethylsiloxane device for monitoring cellular release with microchip electrophoresis and electrochemical detection.

Authors:  Alicia S Johnson; Benjamin T Mehl; R Scott Martin
Journal:  Anal Methods       Date:  2015-02-07       Impact factor: 2.896

Review 2.  Micro total analysis systems: fundamental advances and biological applications.

Authors:  Christopher T Culbertson; Tom G Mickleburgh; Samantha A Stewart-James; Kathleen A Sellens; Melissa Pressnall
Journal:  Anal Chem       Date:  2013-12-13       Impact factor: 6.986

3.  Isolation of target DNA using synergistic magnetic bead transport and electrokinetic flow.

Authors:  Lindsay Schneider; Francis Cui; Anubhav Tripathi
Journal:  Biomicrofluidics       Date:  2021-03-17       Impact factor: 2.800

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.