Comparing ophthalmoscopy, slide viewing, and semiautomated systems in optic disc morphometry.

M Kamran Ikram1, Petra H Borger, Jacqueline J M Assink, Jost B Jonas, Albert Hofman, Paulus T V M de Jong.   

Abstract

PURPOSE: To compare disc measurements obtained by indirect ophthalmoscopy, the Heidelberg Retina Tomograph (HRT), stereoscopic slide viewing (SSV) of color transparencies, and the Topcon ImageNet System (ImageNet).
DESIGN: Population-based cross-sectional study.
METHODS: From the Rotterdam Study, 324 subjects (567 eyes) were nonselectively included. All underwent a full ophthalmologic examination in mydriasis. Vertical cup/disc ratios (VCDRs) were compared between all four methods and disc area (mm(2)), neural rim area (mm(2)), cup area (mm(2)), and cup volume (mm(3)) between HRT and ImageNet.
RESULTS: Mean VCDR for ophthalmoscopy was 0.25 (standard error [SE], 0.007), for HRT 0.42 (SE, 0.008), for SSV 0.39 (SE, 0.010), and for ImageNet 0.50 (SE, 0.006). The correlation for VCDR between ophthalmoscopy, the two devices, and SSV was 0.42, respectively 0.57; between ImageNet and HRT 0.75. The 97.5th percentiles of the VCDR for ophthalmoscopy, HRT, SSV, and ImageNet were 0.80, 0.73, 0.80, and 0.73, respectively; the 99.5th percentiles thus were 0.90, 0.79, 0.86, and 0.79. The mean disc area, rim area, cup area, and cup volume were 2.08, 1.63, 0.45 mm(2) and 0.09 mm(3) for HRT, and 2.39, 1.77, 0.61 mm(2) and 0.16 mm(3) for ImageNet, respectively. The corresponding correlations for these four parameters were 0.67, 0.42, 0.81, and 0.82.
CONCLUSIONS: Different techniques lead to considerable differences in disc morphometric values. ImageNet produced higher mean values compared with HRT and ophthalmoscopy. Ophthalmoscopy showed the lowest correlations and SSV the highest ones with the two semiautomated devices. Between ImageNet and HRT the correlation for all parameters was high except for the neural rim area.

Entities:  

Mesh:

Year:  2002        PMID: 11874749     DOI: 10.1016/s0161-6420(01)00983-6

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  7 in total

1.  Comparison of optic nerve head assessment with a digital stereoscopic camera (discam), scanning laser ophthalmoscopy, and stereophotography.

Authors:  Anthony J Correnti; Gadi Wollstein; Lori Lyn Price; Joel S Schuman
Journal:  Ophthalmology       Date:  2003-08       Impact factor: 12.079

2.  Agreement between optical coherence tomography and digital stereophotography in vertical cup-to-disc ratio measurement.

Authors:  Giacomo Savini; Edgar M Espana; Ana Carolina Acosta; Michele Carbonelli; Costantino Bellusci; Piero Barboni
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-10-29       Impact factor: 3.117

Review 3.  Test-retest variability in structural parameters measured with glaucoma imaging devices.

Authors:  Makoto Araie
Journal:  Jpn J Ophthalmol       Date:  2012-11-09       Impact factor: 2.447

4.  A genome-wide association study of optic disc parameters.

Authors:  Wishal D Ramdas; Leonieke M E van Koolwijk; M Kamran Ikram; Nomdo M Jansonius; Paulus T V M de Jong; Arthur A B Bergen; Aaron Isaacs; Najaf Amin; Yurii S Aulchenko; Roger C W Wolfs; Albert Hofman; Fernando Rivadeneira; Ben A Oostra; Andre G Uitterlinden; Pirro Hysi; Christopher J Hammond; Hans G Lemij; Johannes R Vingerling; Caroline C W Klaver; Cornelia M van Duijn
Journal:  PLoS Genet       Date:  2010-06-10       Impact factor: 5.917

5.  False negative results in glaucoma detection with Heidelberg Retina Tomograph II.

Authors:  Catherine Deghislage; Lidwine Van Malderen; Thierry G Zeyen
Journal:  Clin Ophthalmol       Date:  2008-03

6.  Retinal vascular abnormalities and their associations with cardiovascular and cerebrovascular diseases: a Study in rural southwestern Harbin, China.

Authors:  Junwei Wang; Fei Leng; Zhijian Li; Xianling Tang; Hua Qian; Xiaoguang Li; Yi Zhang; Xuedong Chen; Haitao Du; Ping Liu
Journal:  BMC Ophthalmol       Date:  2020-04-06       Impact factor: 2.209

7.  Comparison of the clinical estimation of cup-to-disk ratio by direct ophthalmoscopy and optical coherence tomography.

Authors:  Angela Ofeibea Amedo; Nana Yaa Koomson; Emmanuel Kobia Acquah; Tchiakpe Michel Pascal; Johnson Atuahene; Prince Kwaku Akowuah; Philip Tetteh Djeagbo; Richard Baafi
Journal:  Ther Adv Ophthalmol       Date:  2019-04-02
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.