Pulse oximetry: a diagnostic instrument in pulpal vitality testing.

Sangeeth Radhakrishnan1, A K Munshi, Amitha M Hegde.   

Abstract

One hundred children with normal maxillary central and lateral incisors were subjected to vitality tests each by electrical and pulse oximetry. As a control population to confirm the readings, 10 known nonvital anterior teeth with complete endodontic fillings were tested. The systemic oxygen saturation values measured on the index finger of the patient served as the control for the comparison of the oxygen saturation values measure on the teeth. The SaO2 values obtained on the teeth were correlated with the electrical test readings. The correlation between the SaO2 readings and electrical testing readings were found to be negative i.e. as the values of the electrical pulp testing reading increased, the SaO2 values decreased. Since a reproducible SaO2 level is obtainable on the vital teeth, pulse oximetry has immediate clinical value in providing base line vitality data for the traumatised teeth.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11874005     DOI: 10.17796/jcpd.26.2.2j25008jg6u86236

Source DB:  PubMed          Journal:  J Clin Pediatr Dent        ISSN: 1053-4628            Impact factor:   1.065


  10 in total

1.  Reference values for pulp oxygen saturation as a diagnostic tool in endodontics: a systematic review and meta-analysis.

Authors:  Paula Lambert; Sergio Augusto Quevedo Miguens; Caroline Solda; Juliana Tomaz Sganzerla; Leandro Azambuja Reichert; Carlos Estrela; Fernando Branco Barletta
Journal:  Restor Dent Endod       Date:  2020-10-05

2.  Evaluation of the Pulp Oxygen Saturation Reading after Tooth Bleaching: A Randomized Clinical Trial.

Authors:  Dilma Helena Neves Henriques; Ana Maria Hecke Alves; Larissa Fernanda Pottmaier; Lucas da Fonseca Roberti Garcia; Eduardo Antunes Bortoluzzi; Cleonice Silveira Teixeira
Journal:  Int J Dent       Date:  2022-04-28

3.  Dental pulp testing: a review.

Authors:  Eugene Chen; Paul V Abbott
Journal:  Int J Dent       Date:  2009-11-12

4.  Evaluation of efficacy of a pulse oximeter to assess pulp vitality.

Authors:  Mohammed Sadique; S V Ravi; Kunjamma Thomas; Prasanth Dhanapal; Elsy P Simon; Mohammed Shaheen
Journal:  J Int Oral Health       Date:  2014-06-26

5.  Evaluation of Nd:YAG laser on partial oxygen saturation of pulpal blood in anterior hypersensitive teeth.

Authors:  Reza Birang; Naser Kaviani; Mehdi Mohammadpour; Ahmad Moghareh Abed; Norbert Gutknecht; Maziar Mir
Journal:  Lasers Med Sci       Date:  2007-07-20       Impact factor: 3.161

6.  Determining the effect of implant surgery on blood oxygen saturation of the adjacent tooth.

Authors:  Nasser Kaviani; Mohammad Shahaboyi; Arezoo Khabazian
Journal:  Dent Res J (Isfahan)       Date:  2012-07

7.  Detection of Pulpal Blood Flow In Vivo with Pulse Oximetry in Dogs.

Authors:  Jessica Riehl; Scott J Hetzel; Christopher J Snyder; Jason W Soukup
Journal:  Front Vet Sci       Date:  2016-05-20

8.  Correlation between Histological Status of the Pulp and Its Response to Sensibility Tests.

Authors:  Mandana Naseri; Akbar Khayat; Sara Zamaheni; Shiva Shojaeian
Journal:  Iran Endod J       Date:  2017

Review 9.  Applications of sensory and physiological measurement in oral-facial dental pain.

Authors:  Darya Dabiri; Daniel E Harper; Yvonne Kapila; Grant H Kruger; Daniel J Clauw; Steven Harte
Journal:  Spec Care Dentist       Date:  2018-09-08

10.  Pulp Vitality Testing with a Developed Universal Pulse Oximeter Probe Holder.

Authors:  Živilė Grabliauskienė; Roberta Zamaliauskienė; Greta Lodienė
Journal:  Medicina (Kaunas)       Date:  2021-01-23       Impact factor: 2.430

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.