Literature DB >> 11872306

Dosimetric intercomparison for two Australasian clinical trials using an anthropomorphic phantom.

Tomas Kron1, Chris Hamilton, Marianne Roff, Jim Denham.   

Abstract

INTRODUCTION: Many different factors can affect the accurate delivery of dose to the clinical target volume in radiotherapy. This is particularly important in the context of multicenter clinical trials where different equipment and techniques may be used for supposedly identical treatments. A dosimetric intercomparison employing an anthropomorphic phantom (level III dosimetric intercomparison) can be used to check many of the factors that could affect treatment by mimicking the radiotherapy pathway of a patient as closely as possible. METHODS AND MATERIALS: An anthropomorphic phantom (ART) was taken to 18 radiotherapy centers in Australia and New Zealand and treated for two different treatment scenarios based on current clinical trials of the Trans-Tasman Radiation Oncology Group (TROG): a two-field treatment of a carcinoma of the tonsil (TROG 91.01), and a four-field prostate treatment (TROG 96.01). The dose distribution was assessed in two consecutive treatments using thermoluminescence dosimeters (TLDs) placed throughout the target volume and in "critical" structures such as the lens of the eye or the rectum. The study also included a check of absolute dose calibration in a slab phantom (level I dosimetric intercomparison). The influence of a variety of treatment parameters on the dose homogeneity in the target and the measured dose in the target and the critical organs was evaluated.
RESULTS: The dose measurements confirmed that in all participating centers the correct dose was delivered to the ICRU reference point (tonsil: 99.8 +/- 2.3%; prostate: 100.9 +/- 1.9% [1 SD]). Also the absolute dose calibration and the mean dose in the target volume were within the specified action levels of plus minus 5% for all participating centers. No influence of shielding, beam modifiers, beam weighting, treatment planning approach (CT, 2D, 3D), and type of equipment used on the dose in the target and its homogeneity could be demonstrated. However, treatment technique and energy used influenced the dose to the critical organs. It was shown that the interpretation of results could be improved by including two complementary treatment scenarios and a level I intercomparison with the level III dosimetric intercomparison.
CONCLUSION: The study demonstrated the feasibility of a level III dosimetric intercomparison service at a cost of approximately $1000(US) per center in Australasia. It confirmed that the dose delivered by all participating centers was as intended in the two treatment scenarios chosen. While this provides reassurance to the oncology community and the general public, the service must be extended to all centers and other potentially more complex treatment scenarios. The present study has built the foundation for this by establishing a baseline and action levels and suggesting improvements in phantom design which will be included in future TROG quality assurance exercises.

Entities:  

Mesh:

Year:  2002        PMID: 11872306     DOI: 10.1016/s0360-3016(01)02682-7

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  6 in total

1.  Credentialing of radiotherapy centres in Australasia for TROG 09.02 (Chisel), a Phase III clinical trial on stereotactic ablative body radiotherapy of early stage lung cancer.

Authors:  Tomas Kron; Brent Chesson; Nicholas Hardcastle; Melissa Crain; Natalie Clements; Mark Burns; David Ball
Journal:  Br J Radiol       Date:  2018-03-06       Impact factor: 3.039

2.  Development of a novel and low-cost anthropomorphic pelvis phantom for 3D dosimetry in radiotherapy.

Authors:  Somayyeh Babaloui; Shakardokht Jafari; Wojciech Polak; Mahdi Ghorbani; Michael Wj Hubbard; Annika Lohstroh; Alireza Shirazi; Ramin Jaberi
Journal:  J Contemp Brachytherapy       Date:  2020-10-30

3.  The Australian Clinical Dosimetry Service: a commentary on the first 18 months.

Authors:  Ivan Williams; John Kenny; Jessica Lye; Joerg Lehmann; Leon Dunn; Tomas Kron
Journal:  Australas Phys Eng Sci Med       Date:  2012-09-28       Impact factor: 1.430

Review 4.  Quality assurance for clinical trials.

Authors:  Geoffrey S Ibbott; Annette Haworth; David S Followill
Journal:  Front Oncol       Date:  2013-12-19       Impact factor: 6.244

5.  The role of medical physicists in clinical trials: More than quality assurance.

Authors:  Tomas Kron
Journal:  J Med Phys       Date:  2013-07

6.  A comparison of IROC and ACDS on-site audits of reference and non-reference dosimetry.

Authors:  Jessica Lye; Stephen Kry; Maddison Shaw; Francis Gibbons; Stephanie Keehan; Joerg Lehmann; Tomas Kron; David Followill; Ivan Williams
Journal:  Med Phys       Date:  2019-10-25       Impact factor: 4.071

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.