High accuracy mass measurement of peptides with internal calibration using a dual electrospray ionization sprayer system for protein identification.

Feng Zhou1, Wenqing Shui, Yu Lu, Pengyuan Yang, Yinlong Guo.   

Abstract

A dual-ESI-sprayer system was constructed and applied to achieve high accuracy of peptide mass measurement for protein identification by means of peptide mapping. Sample was introduced in one sprayer, and reference in the other, thus making internal calibration possible greatly enhancing the mass accuracy. Several samples were utilized to evaluate the reliability of this dual-ESI-sprayer system. The range of mass errors was 0.16-5.37 ppm. The peptide masses of tryptic digests of myoglobin (horse) were measured by the HPLC/dual-ESI-MS system, with mass deviations ranging from 0.01-7.67 ppm, and about 75% mass deviations below 5 ppm with 40% below 1[?]ppm. These peptide masses were utilized to perform database searching for protein identification, and compared to results obtained by external calibration. This comparison showed that the internal calibration provides a more reliable method of protein identification, with a much smaller number of required peptides for matching, and with less CPU time consumed for database searching. Copyright 2002 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11870887     DOI: 10.1002/rcm.603

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  4 in total

Review 1.  Accurate mass measurements in proteomics.

Authors:  Tao Liu; Mikhail E Belov; Navdeep Jaitly; Wei-Jun Qian; Richard D Smith
Journal:  Chem Rev       Date:  2007-07-25       Impact factor: 60.622

2.  Pulsed dual electrospray ionization for ion/ion reactions.

Authors:  Yu Xia; Xiaorong Liang; Scott A McLuckey
Journal:  J Am Soc Mass Spectrom       Date:  2005-09-22       Impact factor: 3.109

3.  Pulsed Nano-Electrospray Ionization: Characterization of Temporal Response and Implementation with a Flared Inlet Capillary.

Authors:  Jared M Bushey; Desmond A Kaplan; Ryan M Danell; Gary L Glish
Journal:  Instrum Sci Technol       Date:  2009       Impact factor: 1.584

Review 4.  Food Phenotyping: Recording and Processing of Non-Targeted Liquid Chromatography Mass Spectrometry Data for Verifying Food Authenticity.

Authors:  Marina Creydt; Markus Fischer
Journal:  Molecules       Date:  2020-08-31       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.