Literature DB >> 11868098

MR evaluation of coronary stents with navigator echo and breath-hold cine gradient-echo techniques.

F Sardanelli1, F Zandrino, G Molinari, A Iozzelli, M Balbi, A Barsotti.   

Abstract

The aim of this study was to evaluate coronary artery stents with MR. Thirty-eight patients underwent MR imaging 48.1 +/- 6.6 days (range 38-60 days) after placement of 47 coronary stents of 11 different types, using navigator echo (NE) and cine gradient-echo (GE) techniques. For both sequences the low signal artifact was used to localize the stent, whereas the flow-related high signal before and distal to the stent was considered as a patency sign. Exercise electrocardiographic test (EET) had been performed 1-7 days before MR. No adverse event with possible relation to the MR examination was observed. All the stents were recognized as signal void with GE, and all but one with NE. Of the 2 patients with positive EET, the first one, with a stent on the left anterior descending coronary artery, presented low signal distal to the stent at both MR sequences, suggesting dysfunction [60% stenosis at conventional coronary angiography (CCA)]; the second one, with two sequential stents on the right coronary artery, presented lack of signal distal to the stents at both MR sequences, suggesting occlusion (97% stenosis at CCA). For the 44 remaining stents in 36 patients with negative EET, MR high signal before and distal to the stent suggested patency at both sequences. MR seems to be a safe and promising technique for non-invasive evaluation of coronary stents.

Entities:  

Mesh:

Year:  2001        PMID: 11868098     DOI: 10.1007/s003300101017

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  5 in total

Review 1.  MRI in coronary artery disease.

Authors:  Jörg Barkhausen; Peter Hunold; Kai-Uwe Waltering
Journal:  Eur Radiol       Date:  2004-09-04       Impact factor: 5.315

2.  64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents.

Authors:  David Maintz; Harald Seifarth; Rainer Raupach; Thomas Flohr; Michael Rink; Torsten Sommer; Murat Ozgün; Walter Heindel; Roman Fischbach
Journal:  Eur Radiol       Date:  2005-12-07       Impact factor: 5.315

Review 3.  Multidetector computed tomography angiography for assessment of in-stent restenosis: meta-analysis of diagnostic performance.

Authors:  Piet K Vanhoenacker; Isabel Decramer; Olivier Bladt; Giovanna Sarno; Erik Van Hul; William Wijns; Ben A Dwamena
Journal:  BMC Med Imaging       Date:  2008-07-31       Impact factor: 1.930

Review 4.  2014 Korean guidelines for appropriate utilization of cardiovascular magnetic resonance imaging: a joint report of the Korean Society of Cardiology and the Korean Society of Radiology.

Authors:  Yeonyee E Yoon; Yoo Jin Hong; Hyung-Kwan Kim; Jeong A Kim; Jin Oh Na; Dong Hyun Yang; Young Jin Kim; Eui-Young Choi
Journal:  Korean J Radiol       Date:  2014-11-07       Impact factor: 3.500

Review 5.  2014 korean guidelines for appropriate utilization of cardiovascular magnetic resonance imaging: a joint report of the korean society of cardiology and the korean society of radiology.

Authors:  Yeonyee E Yoon; Yoo Jin Hong; Hyung-Kwan Kim; Jeong A Kim; Jin Oh Na; Dong Hyun Yang; Young Jin Kim; Eui-Young Choi
Journal:  Korean Circ J       Date:  2014-11-25       Impact factor: 3.243

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.