Literature DB >> 11867810

Cardiac function: MR evaluation in one breath hold with real-time true fast imaging with steady-state precession.

Vivian S Lee1, Daniel Resnick, Jeffrey M Bundy, Orlando P Simonetti, Peter Lee, Jeffrey C Weinreb.   

Abstract

In 12 healthy volunteers and eight patients with cardiac disease, cine magnetic resonance (MR) imaging in the heart was performed with real-time true fast imaging with steady-state precession (FISP), which permitted evaluation of the entire left ventricle in one breath hold (91 msec per frame, 13 frames per section position, nine short-axis section positions per breath hold). Contrast-to-noise ratios (CNRs) and left ventricular mass and function measurements with this technique were compared in all subjects with single-section true FISP imaging and, in the volunteers only, with segmented fast low-angle shot (FLASH) MR imaging. Myocardium-to-blood CNR was significantly higher for both true FISP sequences compared with the FLASH sequence. Measurements of resting left ventricular function with real-time true FISP imaging were comparable with those derived from a series of separate breath-hold single-section true FISP acquisitions.

Entities:  

Mesh:

Year:  2002        PMID: 11867810     DOI: 10.1148/radiol.2223011156

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  25 in total

1.  Dual breath-hold magnetic resonance cine evaluation of global and regional cardiac function.

Authors:  Bernd J Wintersperger; Spencer Sincleair; Val M Runge; Olaf Dietrich; Armin Huber; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2006-04-22       Impact factor: 5.315

2.  High-resolution MRI of cardiac function with projection reconstruction and steady-state free precession.

Authors:  Dana C Peters; Daniel B Ennis; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2002-07       Impact factor: 4.668

3.  Single breath-hold real-time cine MR imaging: improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithm.

Authors:  Bernd J Wintersperger; Konstantin Nikolaou; Olaf Dietrich; Johannes Rieber; Matthias Nittka; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2003-05-29       Impact factor: 5.315

4.  Three-dimensional true FISP for high-resolution imaging of the whole brain.

Authors:  B Schmitz; T Hagen; W Reith
Journal:  Eur Radiol       Date:  2003-02-26       Impact factor: 5.315

Review 5.  Magnetic resonance imaging assessment of cardiac function.

Authors:  W Gregory Hundley; Craig A Hamilton; Pairoj Rerkpattanapipat
Journal:  Curr Cardiol Rep       Date:  2003-01       Impact factor: 2.931

6.  Signal-to-noise ratio behavior of steady-state free precession.

Authors:  Scott B Reeder; Daniel A Herzka; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2004-07       Impact factor: 4.668

7.  [Determining global heart function with real time TrueFISP in one respiratory cycle].

Authors:  B J Wintersperger; K Nikolaou; O Mühling; A Huber; O Dietrich; M Nittka; B Kiefer; M F Reiser; S O Schoenberg
Journal:  Radiologe       Date:  2004-02       Impact factor: 0.635

8.  Single heartbeat cardiac tagging for the evaluation of transient phenomena.

Authors:  Daniel A Herzka; J Andrew Derbyshire; Peter Kellman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2005-12       Impact factor: 4.668

9.  Assessment of global left ventricular functional parameters: analysis of every second short-axis Magnetic Resonance Imaging slices is as accurate as analysis of consecutive slices.

Authors:  Daniel D Lubbers; Tineke P Willems; Pieter A van der Vleuten; Jelle Overbosch; Marco J W Götte; Dirk J van Veldhuisen; Matthijs Oudkerk
Journal:  Int J Cardiovasc Imaging       Date:  2007-06-28       Impact factor: 2.357

10.  Assessment of left ventricular volumes and function by cine-MR imaging depending on the investigator's experience.

Authors:  A Bailly; J Lipiecki; P Chabrot; A Alfidja; J M Garcier; S Ughetto; J Ponsonnaille; L Boyer
Journal:  Surg Radiol Anat       Date:  2008-10-08       Impact factor: 1.246

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.