Literature DB >> 11866197

Configural display design techniques considered at multiple levels of evaluation.

K B Bennett1, B Walters.   

Abstract

Two studies were conducted to examine issues in the design and evaluation of configural displays. Four design techniques (bar graphs/extenders, scale markers/ scale grids, color coding/color layering/color separation, and annotation with digital values) were applied, alone and in combination, to a baseline configural display, forming 10 displays. Two qualitatively different evaluations assessed performance for (A) low-level data probes (quantitative estimates of individual variables) and (B) system control and fault detection tasks. Three of the four design techniques improved performance significantly for low-level data probes (color coding was the exception). A display with digital values only (i.e., no analog configural display) produced the poorest performance for control/fault detection tasks. When both levels of evaluation are considered, a composite display (configural display with all four techniques applied) was clearly the most effective. Overall, the findings obtained in the two experiments provide very limited evidence for the generalization of results between evaluations. The two levels of evaluation, the display manipulations, and the patterns of results are considered in terms of a cognitive systems engineering evaluation framework. General implications for the evaluation of displays and interfaces are discussed. Actual or potential applications include design techniques to improve graphical displays and methodological insights to focus and improve evaluation efforts.

Mesh:

Year:  2001        PMID: 11866197     DOI: 10.1518/001872001775898304

Source DB:  PubMed          Journal:  Hum Factors        ISSN: 0018-7208            Impact factor:   2.888


  4 in total

1.  The employment of an iterative design process to develop a pulmonary graphical display.

Authors:  S Blake Wachter; Jim Agutter; Noah Syroid; Frank Drews; Matthew B Weinger; Dwayne Westenskow
Journal:  J Am Med Inform Assoc       Date:  2003-03-28       Impact factor: 4.497

2.  Reducing post analytical error: perspectives on new formats for the blood sciences pathology report.

Authors:  John D O'Connor
Journal:  Clin Biochem Rev       Date:  2015-02

3.  The evaluation of a pulmonary display to detect adverse respiratory events using high resolution human simulator.

Authors:  S Blake Wachter; Ken Johnson; Robert Albert; Noah Syroid; Frank Drews; Dwayne Westenskow
Journal:  J Am Med Inform Assoc       Date:  2006-08-23       Impact factor: 4.497

4.  Creation and validation of the pictorial ecological momentary well-being instrument (EMOWI) for adolescents.

Authors:  Marie Buzzi; Laetitia Minary; Yan Kestens; Nelly Agrinier; Laetitia Ricci; Jonathan Epstein
Journal:  Qual Life Res       Date:  2022-01-07       Impact factor: 3.440

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.