Literature DB >> 11866062

An optical fiber chemical sensor for mercury ions based on a porphyrin dimer.

Xiao-Bing Zhang1, Can-Cheng Guo, Zhi-Zhang Li, Guo-Li Shen, Ru-Qin Yu.   

Abstract

The synthesis of a novel fluoroionophore, 5-p-[[4-(10',15',20'-triphenyl-5'-porphinato) phenyloxyl]-1-butyloxyl]phenyl-10,15,20-triphenylporphine (DTPP), and its application for preparation of a Hg(II)-sensitive optical fiber chemical sensor are described. The response of the sensor is based on the fluorescence quenching of DTPP by coordination with Hg(II). The porphyrin dimer-based sensor shows a linear response toward Hg(II) in the concentration range 5.2 x 10(-7)-3.1 x 10(-4) mol x L(-1), with a working pH range from 2.4 to 8.0. The sensor shows excellent selectivity for Hg(II) over transition metal cations including Cd(II), Co(II), Cu(II), Ni(II), Pb(II), Zn(II), and Fe(III). As a sensing agent, the porphyrin dimer shows obviously better fluorescence response characteristics toward Hg(II) compared to porphyrin monomer or metalloporphyrin. The effect of the composition of the sensor membrane was studied, and the experimental conditions were optimized. The sensor has been used for determination of Hg(II) in water samples.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11866062     DOI: 10.1021/ac0109218

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

1.  Aptamer-functionalized porous phospholipid nanoshells for direct measurement of Hg(2+) in urine.

Authors:  Zhen Li; Thusitha P Muhandiramlage; John P Keogh; Henry K Hall; Craig A Aspinwall
Journal:  Anal Bioanal Chem       Date:  2014-10-19       Impact factor: 4.142

2.  A novel Hg2+ selective ratiometric fluorescent chemodosimeter based on an intramolecular FRET mechanism.

Authors:  Gui-Qin Shang; Xia Gao; Mei-Xiu Chen; Hong Zheng; Jin-Gou Xu
Journal:  J Fluoresc       Date:  2008-05-11       Impact factor: 2.217

3.  A Miniaturized Therapeutic Chromophore for Multiple Metal Pollutant Sensing, Pathological Metal Diagnosis and Logical Computing.

Authors:  Bhimsen Rout
Journal:  Sci Rep       Date:  2016-06-07       Impact factor: 4.379

4.  A Turn-On Fluorescence-Based Fibre Optic Sensor for the Detection of Mercury.

Authors:  T Hien Nguyen; Tong Sun; Kenneth T V Grattan
Journal:  Sensors (Basel)       Date:  2019-05-09       Impact factor: 3.576

Review 5.  Recent Advances in Porphyrin-Based Materials for Metal Ions Detection.

Authors:  Zhen-Li Qi; Yun-Hui Cheng; Zhou Xu; Mao-Long Chen
Journal:  Int J Mol Sci       Date:  2020-08-14       Impact factor: 5.923

6.  Fused Nickel(II) Porphyrins-Sensing of Toxic Anions and Selected Metal Ions Through Supramolecular Interactions.

Authors:  Tawseef Ahmad Dar; Muniappan Sankar
Journal:  Front Chem       Date:  2020-11-17       Impact factor: 5.221

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.