[Corneal topography and pachymetry in normal eyes].

Z Liu1, Y Xie, M Zhang.   

Abstract

OBJECTIVE: To evaluate the corneal topography and pachymetry on normal eyes.
METHODS: The Orbscan corneal topography system was used to investigate corneal topography and pachymetry on 46 normal subjects.
RESULTS: In normal eyes, island-shape was the most common type in the elevation topography of anterior corneal surface, followed by incomplete ridge, regular ridge, irregular ridge and unclassified type. For the elevation topography of posterior corneal surface, the most common type was also the island-shape, followed by regular ridge, incomplete ridge and irregular ridge. The thinnest point of cornea in normal eyes was located (0.90 plus minus 0.51) mm away from the visual axis with the thickness of (0.55 plus minus 0.33) mm, which was commonly seen at the inferotemporal quarter of cornea, followed by superotemporal, inferonasal and superonasal quarter. The mean corneal thickness was the least in corneal center and greatest in superior part of cornea. For the color-coded map of corneal thickness, oval shape was the commonest type, followed by round shape, eccentric oval shape and eccentric round shape.
CONCLUSIONS: The normal parameters on pan-corneal thickness and corneal shape of both anterior and posterior surface will provide much more useful informations in finding abnormal cornea. Orbscan topography system is a useful instrument for the evaluation of corneal shape and thickness, which is helpful in corneal refractive surgeries.

Entities:  

Mesh:

Year:  2001        PMID: 11864407

Source DB:  PubMed          Journal:  Zhonghua Yan Ke Za Zhi        ISSN: 0412-4081


  3 in total

1.  Using LaserSight Astrapro Planner 2.2 Z software in corneal topography-guided laser in situ keratomileusis for myopia with asymmetric corneal shape.

Authors:  Bing Liu; Wei Chen; De-Wang Shao; Hua Wang; Hai-Xia Ru; Min Zhang; Ying Wang; Chun-Yan Yang
Journal:  Int J Ophthalmol       Date:  2014-06-18       Impact factor: 1.779

2.  Precision and agreement of corneal power measurements obtained using a new corneal topographer OphthaTOP.

Authors:  Jinhai Huang; Giacomo Savini; Hao Chen; Fangjun Bao; Yuanguang Li; Haisi Chen; Weicong Lu; Ye Yu; Qinmei Wang
Journal:  PLoS One       Date:  2015-01-05       Impact factor: 3.240

3.  Relationship between vessel diameter and depth measurements within the limbus using ultra-high resolution optical coherence tomography.

Authors:  Emmanuel Alabi; Natalie Hutchings; Kostadinka Bizheva; Trefford Simpson
Journal:  J Optom       Date:  2017-06-17
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.