Literature DB >> 11861341

The HemoCue, a point of care B-hemoglobin photometer, measures hemoglobin concentrations accurately when mixed in vitro with canine plasma and three hemoglobin-based oxygen carriers (HBOC).

Jonathan S Jahr1, Fedor Lurie, Bernd Driessen, Jessica A Davis, Robert Gosselin, Robert A Gunther.   

Abstract

PURPOSE: Accuracy of measurement of low hemoglobin concentrations using the HemoCue, a B-hemoglobin photometer (HemoCue AB, Angelholm, Sweden) may exhibit significant variability. Infusion of hemoglobin-based oxygen carriers (HBOC) results in low concentrations of plasma hemoglobin. Our study assessed B-hemoglobin photometer measurement accuracy of three HBOC: (hemoglobin glutamer-200 (bovine; Oxyglobin, Biopure Corp., Cambridge, MA, USA); hemoglobin glutamer-250 (bovine; Hemopure, Biopure Corp, Cambridge, MA, USA), and hemoglobin-raffimer, (human; Hemolink, Hemosol, Inc., Toronto, Ontario, Canada).
METHODS: In the laboratory, 45 split canine plasma samples were mixed with hemoglobin glutamer-200 (8.13, 16.25, 32.5 g x L(-1) concentrations), 45 samples were mixed with hemoglobin glutamer-250 (8.13, 16.25, 32.5 g x L(-1) concentrations), 45 with hemoglobin-raffimer (12.5, 25.0, 50.0 g x L(-1) concentrations), and measured. Plasma samples without HBOC served as control. Hemoglobin concentration was determined by a laboratory analyzer (Coulter Corporation, Hiafeah, FL, USA) and B-hemoglobin photometer (HemoCue, Angelholm, Sweden). Two independent technicians performed blinded sample measurements and randomly tested each sample five times. Results were analyzed according to Bland and Altman analysis.
RESULTS: B-hemoglobin photometer demonstrated high repeatability for all three HBOCs. Repeatability coefficients were 0.37 g x L(-1) and 0.48 g x L(-1) for hemoglobin glutamer-200, 0.39 g x L(-1) and 0.4 g x L(-1) for hemoglobin glutamer-250 and 1.07 g x L(-1) and 0.85 g x L(-1) for hemoglobin-raffimer. An acceptable agreement was found between the B-hemoglobin photometer and the laboratory analyzer for all three HBOCs tested.
CONCLUSION: The B-hemoglobin photometer accurately determined the concentration of three HBOC solutions dissolved in canine plasma.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11861341     DOI: 10.1007/bf03020522

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  7 in total

1.  Comparison of HemoCue® hemoglobin-meter and automated hematology analyzer in measurement of hemoglobin levels in pregnant women at Khartoum hospital, Sudan.

Authors:  Ishag Adam; Samah Ahmed; Mahmoud H Mahmoud; Mohammed I Yassin
Journal:  Diagn Pathol       Date:  2012-03-21       Impact factor: 2.644

2.  Resuscitation from hemorrhagic shock using polymerized hemoglobin compared to blood.

Authors:  Daniel Ortiz; Marcelo Barros; Su Yan; Pedro Cabrales
Journal:  Am J Emerg Med       Date:  2013-12-07       Impact factor: 2.469

3.  Broadband diffuse optical spectroscopy assessment of hemorrhage- and hemoglobin-based blood substitute resuscitation.

Authors:  Jangwoen Lee; Jae G Kim; Sari Mahon; Bruce J Tromberg; David Mukai; Kelly Kreuter; Darin Saltzman; Renee Patino; Robert Goldberg; Matthew Brenner
Journal:  J Biomed Opt       Date:  2009 Jul-Aug       Impact factor: 3.170

4.  Application of negative tissue interstitial pressure improves functional capillary density after hemorrhagic shock in the absence of volume resuscitation.

Authors:  Vinay P Jani; Vivek P Jani; Carlos J Munoz; Krianthan Govender; Alexander T Williams; Pedro Cabrales
Journal:  Physiol Rep       Date:  2021-03

5.  Hemoglobin estimation by the HemoCue® portable hemoglobin photometer in a resource poor setting.

Authors:  Bernard Nkrumah; Samuel Blay Nguah; Nimako Sarpong; Denise Dekker; Ali Idriss; Juergen May; Yaw Adu-Sarkodie
Journal:  BMC Clin Pathol       Date:  2011-04-21

6.  Comparison of Performance of Digital Hemoglobinometer over Automated Hematology Analyzer for Hemoglobin Estimation and Its user-friendliness among the Pregnant Women in Selected District Hospitals of Madhya Pradesh.

Authors:  Manju Toppo; Dinesh Kumar Pal; Devendra Gour; Veena Melwani; Manju Dubey; Archana Mishra
Journal:  Indian J Community Med       Date:  2019 Jan-Mar

7.  Blood substitutes: Basic science, translational studies and clinical trials.

Authors:  Jonathan S Jahr
Journal:  Front Med Technol       Date:  2022-08-18
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.