Fatigue damage of human tendons.

H Schechtman1, D L Bader.   

Abstract

The study was designed to examine the effects of partial fatigue on specific mechanical parameters which characterise human tendons in vitro. Specimens prepared from 12 intact Extensor digitorum longus tendons of the foot were subjected to partial fatigue, equivalent to 25% of the median fatigue life, by a cyclic square tension-tension stress waveform at the physiological frequency of 4 Hz. The maximum stress was set at a value corresponding to 20% of the calculated ultimate tensile strength (UTS) of 100 MPa. The minimum stress was set at 1% of the UTS. Dynamic characterisation was performed at stress levels of 10% and 20% of the UTS prior to and following partial mechanical fatigue. Subsequent quasi-static tests were performed on some of the specimens. Comparative analysis of the damage ratios (DRs) of quasi-static and dynamic mechanical parameters suggested the use of the DR for dynamic tensile modulus as a good indicator of damage inflicted by mechanical fatigue. Such an approach might be used for an in vivo assessment of tendon damage.

Entities:  

Mesh:

Year:  2002        PMID: 11858810     DOI: 10.1016/s0021-9290(01)00177-4

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  18 in total

1.  Fatigue life of bovine meniscus under longitudinal and transverse tensile loading.

Authors:  Jaremy J Creechley; Madison E Krentz; Trevor J Lujan
Journal:  J Mech Behav Biomed Mater       Date:  2016-12-27

2.  [Structure and behavior of tendons and ligaments].

Authors:  A Zschäbitz
Journal:  Orthopade       Date:  2005-06       Impact factor: 1.087

3.  A finite dissipative theory of temporary interfibrillar bridges in the extracellular matrix of ligaments and tendons.

Authors:  P Ciarletta; M Ben Amar
Journal:  J R Soc Interface       Date:  2008-12-23       Impact factor: 4.118

4.  Investigation of the mechanical properties of the plantar aponeurosis.

Authors:  P G Pavan; C Stecco; S Darwish; A N Natali; R De Caro
Journal:  Surg Radiol Anat       Date:  2011-09-25       Impact factor: 1.246

5.  Cavitation-induced damage of soft materials by focused ultrasound bursts: A fracture-based bubble dynamics model.

Authors:  Pooya Movahed; Wayne Kreider; Adam D Maxwell; Shelby B Hutchens; Jonathan B Freund
Journal:  J Acoust Soc Am       Date:  2016-08       Impact factor: 1.840

6.  Prevalence of morphological and mechanical stiffness alterations of mid Achilles tendons in asymptomatic marathon runners before and after a competition.

Authors:  C C Ooi; M E Schneider; P Malliaras; P Counsel; D A Connell
Journal:  Skeletal Radiol       Date:  2015-03-19       Impact factor: 2.199

7.  Biomechanical and structural response of healing Achilles tendon to fatigue loading following acute injury.

Authors:  Benjamin R Freedman; Joseph J Sarver; Mark R Buckley; Pramod B Voleti; Louis J Soslowsky
Journal:  J Biomech       Date:  2013-11-11       Impact factor: 2.712

8.  Response of tibialis anterior tendon to a chronic exposure of stretch-shortening cycles: age effects.

Authors:  James S Ensey; Melinda S Hollander; John Z Wu; Michael L Kashon; Brent B Baker; Robert G Cutlip
Journal:  Biomed Eng Online       Date:  2009-06-29       Impact factor: 2.819

9.  Early response to tendon fatigue damage accumulation in a novel in vivo model.

Authors:  David T Fung; Vincent M Wang; Nelly Andarawis-Puri; Jelena Basta-Pljakic; Yonghui Li; Damien M Laudier; Hui B Sun; Karl J Jepsen; Mitchell B Schaffler; Evan L Flatow
Journal:  J Biomech       Date:  2009-11-25       Impact factor: 2.712

10.  Validation of an empirical damage model for aging and in vivo injury of the murine patellar tendon.

Authors:  Mark R Buckley; Andrew A Dunkman; Katherine E Reuther; Akash Kumar; Lydia Pathmanathan; David P Beason; David E Birk; Louis J Soslowsky
Journal:  J Biomech Eng       Date:  2013-04       Impact factor: 2.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.