Literature DB >> 11853237

A comparative study of root canal preparation using Profile .04 and Lightspeed rotary Ni-Ti instruments.

J Versümer1, M Hülsmann, F Schäfers.   

Abstract

AIM: The purpose of this Study was to compare several parameters of root canal preparation using two different rotary nickel-titanium instruments: ProFile .04 (Dentsply/ Maillefer, Ballaigues, Switzerland) and Lightspeed (Lightspeed Technology Inc., San Antonio, TX, USA).
METHODOLOGY: Fifty extracted mandibular molars with root canal curvatures between 20 degrees and 40 degrees were divided into two similar groups having equal mean curvatures. The teeth were then embedded into a muffle system as described by Bramante et al. (1987) and modified by Hülsmann et al. (1999b). All root canals were prepared using ProFile .04 or Lightspeed Ni-Ti instruments to size 45 following the manufacturers' instructions. The Lightspeed system was used in a step-back technique: ProFile .04 instruments were used in a crown-down technique. The following parameters were evaluated: straightening of curved root canals (superimposition of pre- and postoperative radiographs), postoperative root canal diameter (superimposition of pre- and postoperative photographs of root canal cross-sections), safety issues (file fractures. perforations, apical blockages, loss of working length) (protocol), cleaning ability (SEM-evaluation of root canal walls using a five-score system for debris and smear layer), and working time (protocol). Statistical analysis was performed using the Wilcoxon test (P < 0.05) for straightening, and Fisher's exact-test (P < 0.05) for comparison of cross-sections, for comparison of contact between pre- and postoperative diameter, root canal cleanliness and working time.
RESULTS: Both Ni-Ti systems maintained curvature well; the mean degree of straightening was less than 1 degrees for both ProFile .04 and for Lightspeed with no statistical significance between the groups. Most procedural incidents occurred with Profile .04 instruments (three fractures), Lightspeed preparation was completed without instrument fractures. Loss of working length, perforations or apical blockage did not occur with either instrument. Following preparation with Profile.04. 64.0% of the root canals had a round, 30.7% an oval, and 5.3% an irregular cross-section, Lightspeed preparation resulted in a round cross-section in 41.3% of cases, an oval shape in 45.3% of cases: 13.3% of cases had an irregular cross-section. No significant differences were found between the two systems. Lightspeed instruments enlarged the root canal more uniformly with no specimen showing 50% or more contact between pre- and postoperative diameter. The difference was statistically significant only for the coronal third of the root canals (P = 0.032). Mean working time was significantly shorter for Profile .04 (105 s) than for Lightspeed (140 s) (P = 0.02). For debris removal Lightspeed achieved the best results (68% scores 1 and 2), followed by Profile .04 (48.4%) with no significant differences between the systems. The results for remaining smear layer were similar: the lowest amount of smear layer on the root canal walls was found after preparation with Lightspeed (30.7% scores 1 and 2). followed by Profile.04 (23.1%). In the coronal third of the root canals Lightspeed performed significantly better than Profile .04 (P = 0.029): in the middle and apical third the differences were not significant.
CONCLUSIONS: Both systems under investigation respected original root canal curvature and were safe to use. Both systems can be recommended for clinical use.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11853237     DOI: 10.1046/j.1365-2591.2002.00454.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  20 in total

1.  Smear Layer Evaluation on Root Canal Preparation with Manual and Rotary Techniques using EDTA as an Irrigant: A Scanning Electron Microscopy Study.

Authors:  M Manjunatha; Kini Annapurna; V Sudhakar; Vc Sunil Kumar; Vinay Kumar Hiremath; Ankur Shah
Journal:  J Int Oral Health       Date:  2013-02-26

2.  Computed Tomographic Evaluation of K3 Rotary and Stainless Steel K File Instrumentation in Primary Teeth.

Authors:  Haridoss Selvakumar; Swaminathan Kavitha; Eapen Thomas; Vasanthakumari Anadhan; Rajendran Vijayakumar
Journal:  J Clin Diagn Res       Date:  2016-01-01

3.  Canal-centering ability: An endodontic challenge.

Authors:  Deivanayagam Kandaswamy; Nagendrababu Venkateshbabu; Ilango Porkodi; Gali Pradeep
Journal:  J Conserv Dent       Date:  2009-01

4.  Centering ability and dentin removal of rotary systems in curved root canals.

Authors:  Saeed Moradi; Ali Talati; Ali Monajem Zadeh
Journal:  Iran Endod J       Date:  2009-07-06

5.  Cone-beam computed tomography analysis of curved root canals after mechanical preparation with three nickel-titanium rotary instruments.

Authors:  Samia M Elsherief; Mohamed K Zayet; Ibrahim M Hamouda
Journal:  J Biomed Res       Date:  2013-06-25

6.  Vertical root fracture resistance and dentinal crack formation of root canal-treated teeth instrumented with different nickel-titanium rotary systems: an in-vitro study.

Authors:  Galvin Sim Siang Lin; Kiran Prabhakar Singbal; Tahir Yusuf Noorani; Raghavendra Penukonda
Journal:  Odontology       Date:  2021-07-16       Impact factor: 2.634

7.  A Survey on NiTi Rotary Instruments Usage by Endodontists and General Dentist in Tehran.

Authors:  Mohammad Ali Mozayeni; Amin Golshah; Nafiseh Nik Kerdar
Journal:  Iran Endod J       Date:  2011-11-15

8.  Fracture strength of mesiobuccal roots following canal preparation with hand and rotary instrumentation: an in vitro study.

Authors:  Maryam Zare Jahromi; Parvin Mirzakouchaki; Elnaz Mousavi; Amir Arsalan Navabi
Journal:  Iran Endod J       Date:  2011-08-15

9.  Influence of ProTaper finishing files and sodium hypochlorite on cleaning and shaping of mandibuldar central incisors--a histological analysis.

Authors:  Flares Baratto-Filho; Denise Piotto Leonardi; João César Zielak; José Roberto Vanni; Sandra Maria Alves Sayão-Maia; Manoel D Sousa-Neto
Journal:  J Appl Oral Sci       Date:  2009 May-Jun       Impact factor: 2.698

10.  Comparative evaluation of the sealing ability of different obturation systems used over apically separated rotary nickel-titanium files: An in vitro study.

Authors:  Krishnakumar Gollahalli Rangappa; Jayshree Hegde; Champa Chikkamallaiah; Kusum Bashetty; Krishna Rashmi; Krishna K Kumar
Journal:  J Conserv Dent       Date:  2013-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.