L-shell x-ray fluorescence measurements of lead in bone: theoretical considerations.

Andrew C Todd1.   

Abstract

This paper reviews several theoretical considerations pertinent to the use of lead L-shell x-rays for the in vivo measurement of lead in bone: the method of correcting for attenuation, the contributions to the measurement uncertainty, interferences, the depth of bone sampled and the signal strength. Both the predicted bone lead concentration and the measurement uncertainty therein are influenced by the choice of linear attenuation coefficient with which to correct for overlying tissue. Measurement uncertainty is also influenced by inter-individual variability in body composition, methodological uncertainty in the ultrasound measurement of overlying tissue thickness and discrepancy between the site of LXRF and the site of ultrasound measurement. Interference with the Pb Lalpha x-rays by As Kalpha has been overstated and is probably negligible, interference from lead in non-bone tissues may not be. The depth of bone from which the signal is obtained and a crude estimate of signal strength are calculated for different bone compositions for both K and L x-ray fluorescence.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11848124     DOI: 10.1088/0031-9155/47/3/310

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Evaluation of a New Optic-Enabled Portable XRF Instrument for Measuring Toxic Metals/Metalloids in Consumer Goods and Cultural Products.

Authors:  Diana Guimarães; Meredith L Praamsma; Patrick J Parsons
Journal:  Spectrochim Acta Part B At Spectrosc       Date:  2016-03-22       Impact factor: 3.752

2.  Comparison of bone lead measured via portable x-ray fluorescence across and within bones.

Authors:  Aaron J Specht; Aisha S Dickerson; Marc G Weisskopf
Journal:  Environ Res       Date:  2019-02-21       Impact factor: 6.498

3.  Neighborhood psychosocial hazards and the association of cumulative lead dose with cognitive function in older adults.

Authors:  Thomas A Glass; Karen Bandeen-Roche; Matthew McAtee; Karen Bolla; Andrew C Todd; Brian S Schwartz
Journal:  Am J Epidemiol       Date:  2009-01-20       Impact factor: 4.897

4.  A novel calibration for L-shell x-ray fluorescence measurements of bone lead concentration using the strontium Kβ/Kαratio.

Authors:  Mihai R Gherase; Blaz Serna; Sarah Kroeker
Journal:  Physiol Meas       Date:  2021-05-14       Impact factor: 2.833

5.  A microbeam grazing-incidence approach to L-shell x-ray fluorescence measurements of lead concentration in bone and soft tissue phantoms.

Authors:  Mihai Raul Gherase; Summer Al-Hamdani
Journal:  Physiol Meas       Date:  2018-03-29       Impact factor: 2.833

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.