A laboratory investigation of the accuracy of two impression techniques for single-tooth implants.

M F Daoudi1, D J Setchell, L J Searson.   

Abstract

PURPOSE: This laboratory study investigated the accuracy of four implant impression procedures using two impression techniques and two different materials.
MATERIALS AND METHODS: A master model was used to produce 40 different stone casts incorporating laboratory implant or abutment analogues from the different combinations of two impression techniques (the repositioning impression coping technique at the implant level and the pickup impression technique at the abutment level) and materials (President polyvinyl siloxane and Impregum F polyether). Variations in the resulting working casts were measured using the Reflex Microscope to derive distances and angles from the three-dimensional coordinates of optical targets that were attached to a test coping placed on the implant analogue and on a reference device positioned on the occlusal surfaces of the casts.
RESULTS: The results showed greater variations in analogue position with the repositioning impression technique than with the pickup technique. The rotational errors were large enough to be of clinical concern. No significant differences were found between polyvinyl siloxane and polyether impression materials for the two tested types of impression techniques.
CONCLUSION: The repositioning impression technique at the implant level can produce less predictable results than the pickup technique at the abutment level. The choice of impression material made no significant difference.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11843452

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  12 in total

Review 1.  Passive Fit in Screw Retained Multi-unit Implant Prosthesis Understanding and Achieving: A Review of the Literature.

Authors:  Muaiyed Mahmoud Buzayan; Norsiah Binti Yunus
Journal:  J Indian Prosthodont Soc       Date:  2013-12-28

2.  Effect of different impression materials and techniques on the dimensional accuracy of implant definitive casts.

Authors:  Behnaz Ebadian; Mansor Rismanchian; Badrosadat Dastgheib; Farshad Bajoghli
Journal:  Dent Res J (Isfahan)       Date:  2015 Mar-Apr

3.  Effect of technique and impression material on the vertical misfit of a screw-retained, three-unit implant bridge: An in vitro study.

Authors:  Hamidreza Rajati Haghi; Masoud Shiehzadeh; Mohammadreza Nakhaei; Fatemeh Ahrary; Saeid Sabzevari
Journal:  J Indian Prosthodont Soc       Date:  2017 Jan-Mar

4.  Accuracy of different impression materials in parallel and nonparallel implants.

Authors:  Mahroo Vojdani; Kianoosh Torabi; Elham Ansarifard
Journal:  Dent Res J (Isfahan)       Date:  2015 Jul-Aug

5.  Comparison of Dimensional Accuracy between Open-Tray and Closed-Tray Implant Impression Technique in 15° Angled Implants.

Authors:  F Balouch; E Jalalian; M Nikkheslat; R Ghavamian; Sh Toopchi; F Jallalian; S Jalalian
Journal:  J Dent (Shiraz)       Date:  2013-09

6.  A comparative analysis of the accuracy of implant master casts fabricated from two different transfer impression techniques.

Authors:  Rupali Patil; Pankaj Kadam; Chetan Oswal; Seema Patil; Shweta Jajoo; Arati Gachake
Journal:  J Int Soc Prev Community Dent       Date:  2016 Mar-Apr

7.  Three-dimensional accuracy of different impression techniques for dental implants.

Authors:  Mohammadreza Nakhaei; Azam S Madani; Azizollah Moraditalab; Hamidreza Rajati Haghi
Journal:  Dent Res J (Isfahan)       Date:  2015 Sep-Oct

8.  The Accuracy of Four Impression-making Techniques in Angulated Implants Based on Vertical Gap.

Authors:  Abolfazl Saboury; Hamid Neshandar Asli; Zahra Dalili Kajan
Journal:  J Dent (Shiraz)       Date:  2017-12

9.  Cast accuracy obtained from different impression techniques at different implant angulations (in vitro study).

Authors:  Enas A Elshenawy; Ahmed M Alam-Eldein; Fadel A Abd Elfatah
Journal:  Int J Implant Dent       Date:  2018-03-20

10.  Can transfer type and implant angulation affect impression accuracy? A 3D in vitro evaluation.

Authors:  Davide Farronato; Pietro Mario Pasini; Veronica Campana; Diego Lops; Lorenzo Azzi; Mattia Manfredini
Journal:  Odontology       Date:  2021-06-01       Impact factor: 2.634

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.