Literature DB >> 11843451

Accuracy of mechanical digitizing with a CAD/CAM system for fixed restorations.

R G Luthardt1, O Sandkuhl, V Herold, M H Walter.   

Abstract

PURPOSE: Most research on the accuracy of dental computer-aided design/manufacturing (CAD/CAM) systems focuses on the marginal gap. A detailed analysis of the various components of CAD/CAM systems (digitizer, software, and milling machine) using this approach is nearly impossible. The purpose of this study was to determine the accuracy of the manual mechanical digitizer of the Precident-DCS system.
MATERIALS AND METHODS: Gauge blocks were aligned to the coordinate planes of the digitizer to determine the point and length measurement uncertainty. The values for each measuring point were compared for statistical differences concerning first versus second operator, pressure, and mode of sensing using analysis of variance. The measurement uncertainty was given by 95th percentiles.
RESULTS: The mean one-dimensional point measurement uncertainty in the Y direction was 11 microm for the first, 8 microm for the second, and 37 microm for both operators. The three-dimensional point measurement uncertainty in the Y direction was 10 microm for the first, 33 microm for the second, and 60 microm for both operators. The point measurement uncertainty was significantly influenced by the pressure during sensing and by the operator as well. There were significant differences between the first and second recordings. The length measurement uncertainty in the Y direction for a gauge block of 20 mm was 52 microm for both operators.
CONCLUSION: The reliability of the manually guided Precident-DCS digitizer is limited because of the significant influence of the operator and the mode of sensing (one or three dimensional). Compared with an automatic digitizing system, the measurement uncertainty of the manually guided digitizer exceeds the values published in the literature.

Entities:  

Mesh:

Year:  2001        PMID: 11843451

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  9 in total

1.  Marginal fit of 3-unit CAD-CAM zirconia frameworks fabricated using cone beam computed tomography scans: an experimental study.

Authors:  Hüseyin Berkay Belgin; Ediz Kale; Tuncer Burak Özçelik; Burak Yilmaz
Journal:  Odontology       Date:  2021-10-19       Impact factor: 2.634

2.  Impact of surface roughness of gypsum materials on adaptation of zirconia cores.

Authors:  Ki-Baek Kim; Jae-Hong Kim; Sa-Hak Kim
Journal:  J Adv Prosthodont       Date:  2015-06-23       Impact factor: 1.904

3.  White light scanner-based repeatability of 3-dimensional digitizing of silicon rubber abutment teeth impressions.

Authors:  Jin-Hun Jeon; Kyung-Tak Lee; Hae-Young Kim; Ji-Hwan Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2013-11-28       Impact factor: 1.904

4.  Cervical and Incisal Marginal Discrepancy in Ceramic Laminate Veneering Materials: A SEM Analysis.

Authors:  Hemalatha Ranganathan; Dhanraj M Ganapathy; Ashish R Jain
Journal:  Contemp Clin Dent       Date:  2017 Apr-Jun

5.  Comparison of clinical fit of three-unit zirconia fixed prostheses fabricated using chairside and labside CAD/CAM systems.

Authors:  Jong-Ju Ahn; Eun-Bin Bae; Wan-Sun Lee; Won-Tak Cho; Jung-Bo Huh
Journal:  J Dent Sci       Date:  2020-04-02       Impact factor: 2.080

6.  Accuracy of Digital Impression Taking Using Intraoral Scanner versus the Conventional Technique.

Authors:  Arash Zarbakhsh; Ezatollah Jalalian; Nazanin Samiei; Mohammad Hossein Mahgoli; Hadi Kaseb Ghane
Journal:  Front Dent       Date:  2021-02-10

7.  Comparison the Marginal and Internal Fit of Metal Copings Cast from Wax Patterns Fabricated by CAD/CAM and Conventional Wax up Techniques.

Authors:  M Vojdani; K Torabi; E Farjood; Aar Khaledi
Journal:  J Dent (Shiraz)       Date:  2013-09

8.  Effect of the Crystallization Process on the Marginal and Internal Gaps of Lithium Disilicate CAD/CAM Crowns.

Authors:  Jae-Hong Kim; Seunghan Oh; Soo-Hyuk Uhm
Journal:  Biomed Res Int       Date:  2016-03-31       Impact factor: 3.411

9.  Biomechanical three-dimensional finite element analysis of monolithic zirconia crown with different cement type.

Authors:  Seung-Ryong Ha
Journal:  J Adv Prosthodont       Date:  2015-12-30       Impact factor: 1.904

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.