Literature DB >> 11839479

Glucose sensor using a microfabricated electrode and electropolymerized bilayer films.

Haesik Yang1, Taek Dong Chung, Youn Tae Kim, Chang Auck Choi, Chi Hoon Jun, Hee Chan Kim.   

Abstract

A new type miniaturized glucose sensor with good selectivity and stable current response has been developed. The structure consists of a recessed rectangular microfabricated platinum electrode, inner layer of two electropolymerized nonconducting films, and outer bilayer of poly(tetrafluoroethylene) (Teflon) and polyurethane (PU) films. Glucose oxidase (GOx) is entrapped during the electropolymerization of a poly(m-phenylenediamine) (PMPD) film in an acetate buffer (AB) solution, on which a highly interference-resistive PMPD film is deposited in a phosphate buffered saline (PBS) solution. The second PMPD film causes no significant decrease in accessibility of glucose to GOx. The inner layer maintains less than 1% permeability to acetaminophen for 12 days. The fairly adhesive outer layer allows stable current response. Due to high permeability, the information about enzyme activity can be obtained without serious error in spite of outer layer intervening between enzymes and solution. The apparent Michaelis-Menten constant and the maximum steady-state current density were 24 mM and 80 microA cm(-2), respectively.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11839479     DOI: 10.1016/s0956-5663(01)00266-4

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

1.  Flow injection measurements of S-nitrosothiols species in biological samples using amperometric nitric oxide sensor and soluble organoselenium catalyst reagent.

Authors:  Chuncui Huang; Elizabeth Brisbois; Mark E Meyerhoff
Journal:  Anal Bioanal Chem       Date:  2011-03-18       Impact factor: 4.142

2.  Modulation of fibroblast inflammatory response by surface modification of a perfluorinated ionomer.

Authors:  Thelma I Valdes; Winston Ciridon; Buddy D Ratner; James D Bryers
Journal:  Biointerphases       Date:  2011-06       Impact factor: 2.456

3.  A miniaturized transcutaneous system for continuous glucose monitoring.

Authors:  Robert A Croce; SanthiSagar Vaddiraju; Jun Kondo; Yan Wang; Liang Zuo; Kai Zhu; Syed K Islam; Diane J Burgess; Fotios Papadimitrakopoulos; Faquir C Jain
Journal:  Biomed Microdevices       Date:  2013-02       Impact factor: 2.838

4.  Design and fabrication of a high-performance electrochemical glucose sensor.

Authors:  Santhisagar Vaddiraju; Allen Legassey; Yan Wang; Liangliang Qiang; Diane J Burgess; Faquir Jain; Fotios Papadimitrakopoulos
Journal:  J Diabetes Sci Technol       Date:  2011-09-01

Review 5.  Non-Invasive Blood Glucose Monitoring Technology: A Review.

Authors:  Liu Tang; Shwu Jen Chang; Ching-Jung Chen; Jen-Tsai Liu
Journal:  Sensors (Basel)       Date:  2020-12-04       Impact factor: 3.576

Review 6.  Exploration of Chitinous Scaffold-Based Interfaces for Glucose Sensing Assemblies.

Authors:  Dipali R Bagal-Kestwal; Been-Huang Chiang
Journal:  Polymers (Basel)       Date:  2019-11-28       Impact factor: 4.329

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.