Literature DB >> 11834061

Clinical outcome in patients with 19-mm and 21-mm St. Jude aortic prostheses: comparison at long-term follow-up.

Aldo D Milano1, Marco De Carlo, Gianclaudio Mecozzi, Alessandro D'Alfonso, Giovanni Scioti, Carmela Nardi, Uberto Bortolotti.   

Abstract

BACKGROUND: Small-sized prostheses for aortic valve replacement may result in residual left ventricular outflow tract obstruction. Aim of the study was to verify whether implantation of 19-mm versus 21-mm St. Jude Medical standard prostheses (St. Jude Medical, Inc, St. Paul, MN) influences long-term clinical outcome.
METHODS: Two hundred twenty-nine patients who underwent aortic valve replacement with 19 mm (group 1, 53 patients) or 21-mm St. Jude Medical standard prostheses (group 2, 176 patients) were included in the study. Mean follow-up of current survivors was 10+/-4 years.
RESULTS: Operative mortality was 7.5% in group 1 and 8.5% in group 2. At discharge, an important patient-prosthesis mismatch (effective orifice area index < or = 0.60 cm2/m2) was present in 18% of group 1 versus 5% in group 2 (p = 0.004). Among patients with body surface area less than 1.70 m2, such mismatch was present in 15% of group 1 versus 2% of group 2 (p = 0.008). At last follow-up New York Heart Association (NYHA) functional class (p < 0.001), left ventricular mass reduction (p = 0.02), mean (p = 0.002) and peak transprosthetic gradients (p < 0.001), and effective orifice area index (p = 0.005) were significantly better in group 2. Freedom from sudden death (92%+/-5% vs 99%+/-1%, p = 0.01), valve-related death (84%+/-6% vs 90%+/-5%, p = 0.02), and cardiac events (56%+/-13% vs 86%+/-4%, p = 0.008), were significantly lower in group 1. Effective orifice area index was an independent predictor of late cardiac events.
CONCLUSIONS: Although long-term results after aortic valve replacement with small-sized St. Jude Medical standard prostheses are satisfactory, 19-mm valve recipients show a high prevalence of important patient-prosthesis mismatch with less evident functional improvement and higher rate of cardiac events, suggesting a very cautious use of this prosthesis.

Entities:  

Mesh:

Year:  2002        PMID: 11834061     DOI: 10.1016/s0003-4975(01)03306-9

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  10 in total

Review 1.  A 44-year experience of prosthetic heart valve implantation at Niigata University Hospital.

Authors:  Jun-ichi Hayashi
Journal:  J Artif Organs       Date:  2012-04-24       Impact factor: 1.731

Review 2.  Prosthesis-patient mismatch: definition, clinical impact, and prevention.

Authors:  P Pibarot; J G Dumesnil
Journal:  Heart       Date:  2005-10-26       Impact factor: 5.994

3.  Prevention of valve prosthesis--patient mismatch before aortic valve replacement: does it matter and is it feasible?

Authors:  Philippe Pibarot; Jean G Dumesnil
Journal:  Heart       Date:  2007-05       Impact factor: 5.994

4.  Prediction of valve prosthesis-patient mismatch prior to aortic valve replacement: which is the best method?

Authors:  Sabine Bleiziffer; Walter B Eichinger; Ina Hettich; Ralf Guenzinger; Daniel Ruzicka; Robert Bauernschmitt; Ruediger Lange
Journal:  Heart       Date:  2006-12-12       Impact factor: 5.994

Review 5.  Update on aortic valve prosthesis-patient mismatch in Japan.

Authors:  Yoshimasa Sakamoto; Kazuhiro Hashimoto
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-04-13

6.  Complications of prosthetic heart valves.

Authors:  Jeanne M Vesey; Catherine M Otto
Journal:  Curr Cardiol Rep       Date:  2004-03       Impact factor: 2.931

7.  Aortic valve replacement with 31- and 33-mm mechanical prostheses: early results.

Authors:  Gaurav Gupta; Ambuj Roy; A Sampath Kumar
Journal:  Tex Heart Inst J       Date:  2004

8.  The Prognostic Significance of Patient-Prosthesis Mismatch after Aortic Valve Replacement.

Authors:  Paolo Nardi; Marco Russo; Guglielmo Saitto; Giovanni Ruvolo
Journal:  Korean J Thorac Cardiovasc Surg       Date:  2018-06-05

Review 9.  Echocardiographic Imaging Challenges in Obesity: Guideline Recommendations and Limitations of Adjusting to Body Size.

Authors:  Maninder Singh; Anuradha Sethi; Abhishek K Mishra; Navin K Subrayappa; Dwight D Stapleton; Patricia A Pellikka
Journal:  J Am Heart Assoc       Date:  2020-01-09       Impact factor: 5.501

10.  Moderate Patient-Prosthesis Mismatch Has No Negative Effect on Patients' Functional Status After Aortic Valve Replacement With CarboMedics Prosthesis.

Authors:  Alireza Alizadeh-Ghavidel; Rasoul Azarfarin; Azin Alizadehasl; Ali Sadeghpour-Tabaei; Ziae Totonchi
Journal:  Res Cardiovasc Med       Date:  2016-03-05
  10 in total