Literature DB >> 11832321

Hybrid external fixation for tibial plateau fractures: clinical and biomechanical correlation.

J Tracy Watson1, Steve Ripple, Susan J Hoshaw, David Fhyrie.   

Abstract

The biomechanical data support the use of tensioned wire fixation to stabilize complex fractures of the proximal tibia. The authors will show that the stability of a four-wire construct is comparable to the gold standard of dual plating internal fixation techniques. Using these techniques, many recent investigators have demonstrated improved clinical results, with average knee scores for most patients ranging from 85 to 90.

Entities:  

Mesh:

Year:  2002        PMID: 11832321     DOI: 10.1016/s0030-5898(03)00080-4

Source DB:  PubMed          Journal:  Orthop Clin North Am        ISSN: 0030-5898            Impact factor:   2.472


  11 in total

1.  CORR Insights®: What Are the Biomechanical Effects of Half-pin and Fine-wire Configurations on Fracture Site Movement in Circular Frames?

Authors:  Kevin Tetsworth
Journal:  Clin Orthop Relat Res       Date:  2016-01-21       Impact factor: 4.176

2.  Outcomes of open bicondylar tibial plateau fractures treated with Ilizarov external fixator with or without minimal internal fixation.

Authors:  Ayman M Ali
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-04-10

Review 3.  Surgical fixation methods for tibial plateau fractures.

Authors:  Iain R McNamara; Toby O Smith; Karen L Shepherd; Allan B Clark; Dominic M Nielsen; Simon Donell; Caroline B Hing
Journal:  Cochrane Database Syst Rev       Date:  2015-09-15

4.  Modified hybrid fixator for high-energy Schatzker V and VI tibial plateau fractures.

Authors:  Hisam Muhamad Ariffin; Nidzwani M Mahdi; Shaharuddin A Rhani; Azmi Baharudin; Mohamad Hassan Shukur
Journal:  Strategies Trauma Limb Reconstr       Date:  2011-02-11

5.  Tibial Plateau Fractures in Elderly Patients.

Authors:  Joshua C Rozell; Krishna C Vemulapalli; Joshua L Gary; Derek J Donegan
Journal:  Geriatr Orthop Surg Rehabil       Date:  2016-06-06

6.  Complex Tibial Plateau Fractures Treated by Hybrid External Fixation System: A correlation of followup computed tomography derived quality of reduction with clinical results.

Authors:  Konstantinos Kateros; Spyridon P Galanakos; Georgios Kyriakopoulos; Stamatios A Papadakis; George A Macheras
Journal:  Indian J Orthop       Date:  2018 Mar-Apr       Impact factor: 1.251

7.  Treatment of Schatzker Type II-VI Tibial Plateau Fractures by Means of Syndesmotaxis Using an Ilizarov External Fixator and Postoperative CT Evaluation.

Authors:  Stamatios A Papadakis; Dimitrios Pallis; Margarita-Michaela Ampadiotaki; Georgios Gourtzelidis; Konstantinos Kateros; George Macheras
Journal:  Cureus       Date:  2021-01-13

8.  Treatment of ipsilateral high energy tibial plateau and calcaneal fractures by a circular wire fixator: a case report.

Authors:  Shabir Ahmed Dhar; Mohammed Farooq Butt; Murtaza Fazal Ali; Mohammed Ramzan Mir; Altaf Ahmed Kawoosa
Journal:  Cases J       Date:  2009-06-03

9.  Bicondylar tibial plateau fractures treated with fine-wire circular external fixation.

Authors:  N Ferreira; L C Marais
Journal:  Strategies Trauma Limb Reconstr       Date:  2014-02-09

10.  The effect of coronal splits on the structural stability of bi-condylar tibial plateau fractures: a biomechanical investigation.

Authors:  Shabnam Samsami; Robert Pätzold; Martin Winkler; Sven Herrmann; Peter Augat
Journal:  Arch Orthop Trauma Surg       Date:  2020-03-26       Impact factor: 3.067

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.