Literature DB >> 11830620

Predictive value of intraosseous venography before percutaneous vertebroplasty.

J Kevin McGraw1, Eric V Heatwole, Bradley T Strnad, Jeffrey S Silber, Shayle B Patzilk, Jeffrey M Boorstein.   

Abstract

PURPOSE: Percutaneous vertebroplasty is a novel approach for treating patients with painful vertebral body compression fractures. The use of intraosseous venography before the percutaneous injection of polymethylmethacrylate (PMMA) is not universally accepted. The purpose of this study was to determine if intraosseous venography predicts PMMA flow characteristics when injected into a vertebral body.
MATERIALS AND METHODS: One hundred thirty-five intraosseous venograms were obtained during 96 vertebroplasty procedures (39 thoracic, 57 lumbar) in 61 patients (49 women, 12 men; age, 36-94 y) over a 32-month period. All venograms were obtained by injecting water-soluble contrast material through the vertebroplasty needle that had been placed percutaneously via a transpedicular approach. The venograms were retrospectively reviewed by the authors and compared in a blinded fashion with the subsequent final vertebroplasty result.
RESULTS: Several venographic patterns were observed: bilateral or unilateral marrow blush with or without venous filling, direct venous filling, leakage of contrast material through an endplate or cortical defect, and stasis within the marrow space. Venograms that demonstrated a bilateral marrow blush predicted flow of PMMA across the midline to adequately fill the contralateral hemivertebrae 95% of the time (40 of 42 cases). A unilateral marrow blush predicted the necessity of a second puncture 97% of the time (32 of 33 cases). Intraosseous venography predicted PMMA entering endplate/cortical defects in all cases (22 of 22) and venous structures in 29% (22 of 75) of cases. Direct venous filling was observed during two vertebroplasty procedures and gelatin foam embolization was performed before PMMA instillation. Stasis of contrast material in the marrow space was observed in 15 cases. Overall, in 83% (80 of 96) of the vertebroplasty procedures, intraosseous venography was believed to predict the flow characteristics of PMMA.
CONCLUSION: Intraosseous venography provides useful information in predicting PMMA flow characteristics within the vertebral body and in predicting potential undesirable sites of cement deposition, such as through cortical defects and within venous structures.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11830620     DOI: 10.1016/s1051-0443(07)61931-9

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  13 in total

1.  Radiation dose to the operator during vertebroplasty: prospective comparison of the use of 1-cc syringes versus an injection device.

Authors:  David F Kallmes; Erwin O; Soma Sinha Roy; Richard G Piccolo; William F Marx; Jae K Lee; Mary E Jensen
Journal:  AJNR Am J Neuroradiol       Date:  2003 Jun-Jul       Impact factor: 3.825

2.  Safety and effectiveness of cervical vertebroplasty: report of a large cohort and systematic review.

Authors:  Frédéric Clarençon; Robert Fahed; Evelyne Cormier; Idriss Haffaf; Jean-Philippe Spano; Eimad Shotar; Kévin Premat; Raphael Bonaccorsi; Vincent Degos; Jacques Chiras
Journal:  Eur Radiol       Date:  2019-11-20       Impact factor: 5.315

3.  Percutaneous cementoplasty.

Authors:  Konstantinos Katsanos; Tarun Sabharwal; Andreas Adam
Journal:  Semin Intervent Radiol       Date:  2010-06       Impact factor: 1.513

Review 4.  [Percutaneous vertebroplasty (pv): indications, contraindications, and technique].

Authors:  R T Hoffmann; T F Jakobs; A Wallnöfer; M F Reiser; T K Helmberger
Journal:  Radiologe       Date:  2003-09       Impact factor: 0.635

Review 5.  Vertebroplasty for osteoporotic spine fracture: prevention and treatment.

Authors:  A Mehbod; S Aunoble; J C Le Huec
Journal:  Eur Spine J       Date:  2003-09-19       Impact factor: 3.134

6.  The Patterns of Intraosseous Venography before Percutaneous Vertebroplasty for Osteoporotic Compression Fractures.

Authors:  Dong-Sung Kim; Jae-Won Doh; Kyeong-Seok Lee; Seok-Mann Yoon; Jai-Joon Shim; Seong-Ho Kim
Journal:  J Korean Neurosurg Soc       Date:  2008-06-20

Review 7.  Complications of percutaneous vertebroplasty and their prevention.

Authors:  J D Laredo; B Hamze
Journal:  Skeletal Radiol       Date:  2004-06-17       Impact factor: 2.199

8.  CT-guided vertebroplasty: analysis of technical results, extraosseous cement leakages, and complications in 500 procedures.

Authors:  Michael Bernhard Pitton; Sascha Herber; Ulrike Koch; Katja Oberholzer; Philip Drees; Christoph Düber
Journal:  Eur Radiol       Date:  2008-06-04       Impact factor: 5.315

Review 9.  Percutaneous vertebroplasty in tumoral osteolysis.

Authors:  T F Jakobs; C Trumm; M Reiser; R T Hoffmann
Journal:  Eur Radiol       Date:  2007-02-03       Impact factor: 7.034

10.  Aortic embolism of cement: a rare complication of lumbar percutaneous vertebroplasty.

Authors:  Nicolas Amoretti; Istvan Hovorka; Pierre-Yves Marcy; Anne Grimaud; Philippe Brunner; Jean-Noel Bruneton
Journal:  Skeletal Radiol       Date:  2007-03-30       Impact factor: 2.128

View more