Literature DB >> 1183033

Applications of statistics in clinical chemistry. A critical evaluation of regression lines.

P J Wakkers, H B Hellendoorn, G J Op de Weegh, W Heerspink.   

Abstract

When two chemical determination methods are compared, a regression line is commonly used to elucidate constant and proportional errors. The classical procedure for the calculation of such a line is compared to the fairly unknown procedures described by Deming and by Bartlett. It is shown that the reliability of the classical procedure is restricted to only some cases. Deming's procedure is more generally applicable and also has the advantage, that estimates are obtained for the random errors in both chemical determination methods. Bartlett's procedure is not recommended.

Mesh:

Substances:

Year:  1975        PMID: 1183033     DOI: 10.1016/0009-8981(75)90199-0

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  9 in total

1.  Performance evaluation of ISFETs and other ISE sensors for whole blood ion assay.

Authors:  J M Thompson
Journal:  Med Biol Eng Comput       Date:  1990-05       Impact factor: 2.602

2.  Alveolar pressure during high-frequency jet ventilation.

Authors:  A J van Vught; A Versprille; J R Jansen
Journal:  Intensive Care Med       Date:  1990       Impact factor: 17.440

3.  Trends in blood lead levels in Christchurch (NZ) and environs 1978-85.

Authors:  D Hinton; P A Coope; W A Malpress; E D Janus
Journal:  J Epidemiol Community Health       Date:  1986-09       Impact factor: 3.710

4.  Use of Deming regression in method-comparison studies.

Authors:  H Konings
Journal:  Surv Immunol Res       Date:  1982

5.  A novel flow cytometric assay for the quantification of adhesion of subsets within a heterogeneous cell population; analysis of lymphocyte function-associated antigen-1 (LFA-1)-mediated binding of bone marrow-derived primary tumour cells of patients with multiple myeloma.

Authors:  E J Ahsmann; R J Benschop; T D de Gruyl; J A Faber; H M Lokhorst; A C Bloem
Journal:  Clin Exp Immunol       Date:  1993-09       Impact factor: 4.330

6.  Validation of a testosterone and dihydrotestosterone liquid chromatography tandem mass spectrometry assay: Interference and comparison with established methods.

Authors:  Christina Wang; Steve Shiraishi; Andrew Leung; Sima Baravarian; Laura Hull; Victor Goh; Paul W N Lee; Ronald S Swerdloff
Journal:  Steroids       Date:  2008-05-21       Impact factor: 2.668

Review 7.  Quality control of drug assays.

Authors:  G Ayers; D Burnett; A Griffiths; A Richens
Journal:  Clin Pharmacokinet       Date:  1981 Mar-Apr       Impact factor: 6.447

8.  Standardization of blood growth hormone levels measured by different kits using a linear structural relationship.

Authors:  Tomohiro Saito; Katsuhiko Tachibana; Akira Shimatsu; Noriyuki Katsumata; Naomi Hizuka; Kenji Fujieda; Susumu Yokoya; Toshiaki Tanaka
Journal:  Clin Pediatr Endocrinol       Date:  2006-08-02

9.  Corrigendum to "Validation of a testosterone and dihydrotestosterone liquid chromatography tandem mass spectrometry assay: interference and comparison with established methods" [Steroids Volume 73, Issue 13, 12 December 2008, Pages 1345-1352].

Authors:  Christina Wang; Steve Shiraishi; Andrew Leung; Sima Baravarian; Laura Hull; Victor Goh; Paul W N Lee; Ronald S Swerdloff
Journal:  Steroids       Date:  2018-07       Impact factor: 2.760

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.