Literature DB >> 11818603

US-guided fine-needle aspiration biopsy of thyroid nodules: adequacy of cytologic material and procedure time with and without immediate cytologic analysis.

Martin E O'Malley1, Michele M Weir, Peter F Hahn, Joseph Misdraji, Bradford J Wood, Peter R Mueller.   

Abstract

PURPOSE: To compare the adequacy of aspirated material and procedure time when performing ultrasonography-guided fine-needle aspiration biopsy of thyroid nodules with and without immediate cytologic analysis of the aspirated sample.
MATERIALS AND METHODS: One hundred twenty-one thyroid nodules were sampled for biopsy in 109 patients. In group A, results of 50 biopsies in which immediate cytologic analysis was performed were retrospectively reviewed for cytologic adequacy. In group B, 50 biopsies were performed without immediate cytologic analysis, and the procedure time was recorded. In group C, 21 biopsies were performed with immediate cytologic analysis, and the procedure time was recorded. Cytologic adequacy rates were compared by using the proportional odds model, and procedure times were compared by using linear regression to adjust for differences in the character of the nodules.
RESULTS: For groups A and C (immediate cytologic analysis performed), the adequacy categories included the following results: 39 (55%) satisfactory, 15 (21%) limited, and 17 (24%) unsatisfactory. For group B (immediate cytologic analysis not performed), the adequacy categories included the following results: 25 (50%) satisfactory, 15 (30%) limited, and 10 (20%) unsatisfactory (Wald test, P =.815). The average procedure time was 12.5 minutes for group B and 44.4 minutes for group C (P <.001).
CONCLUSION: There was no significant difference in cytologic adequacy whether immediate cytologic analysis of aspirated material was performed or not. The procedure time was significantly shorter when immediate cytologic analysis was not performed.

Entities:  

Mesh:

Year:  2002        PMID: 11818603     DOI: 10.1148/radiol.2222010201

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  20 in total

1.  Ultrasound-based diagnostic classification for solid and partially cystic thyroid nodules.

Authors:  D W Kim; J S Park; H S In; H J Choo; J H Ryu; S J Jung
Journal:  AJNR Am J Neuroradiol       Date:  2012-02-02       Impact factor: 3.825

2.  Diagnostic accuracy of fine-needle aspiration versus core-needle biopsy for the diagnosis of thyroid malignancy in a clinical cohort.

Authors:  Jin Yong Sung; Dong Gyu Na; Kyu Sun Kim; Hyunju Yoo; Hunkyung Lee; Ji-Hoon Kim; Jung Hwan Baek
Journal:  Eur Radiol       Date:  2012-03-14       Impact factor: 5.315

3.  Role of sonographic diagnosis in managing Bethesda class III nodules.

Authors:  D W Kim; E J Lee; S J Jung; J H Ryu; Y M Kim
Journal:  AJNR Am J Neuroradiol       Date:  2011-09-15       Impact factor: 3.825

4.  Comparison of sample adequacy, pain-scale ratings, and complications associated with ultrasound-guided fine-needle aspiration of thyroid nodules between two radiologists with different levels of experience.

Authors:  Yoo Jin Lee; Dong Wook Kim; Soo Jin Jung
Journal:  Endocrine       Date:  2013-02-21       Impact factor: 3.633

5.  Is there a role for on-site evaluation of thyroid fine needle aspiration to reduce the nondiagnostic rate?

Authors:  Gulcin Guler Simsek; Derun Taner Ertuğrul; Servet Guresci; Hülya Şimşek
Journal:  Endocr Pathol       Date:  2013-06       Impact factor: 3.943

6.  The value of ultrasound elastography-guided fine-needle aspiration biopsy of thyroid nodules in reducing nondiagnostic results.

Authors:  Duzgun Yildirim; Bengi Gurses; Berk Gurpinar; Baki Ekci; Bulent Colakoglu; Mutlu Sahin; Ahmet Kaur
Journal:  J Med Ultrason (2001)       Date:  2012-11-14       Impact factor: 1.314

7.  This 'Rose' Has no Thorns-Diagnostic Utility of 'Rapid On-Site Evaluation' (ROSE) in Fine Needle Aspiration Cytology.

Authors:  Kanchan Kothari; Santosh Tummidi; Mona Agnihotri; Pragati Sathe; Leena Naik
Journal:  Indian J Surg Oncol       Date:  2019-09-12

8.  Combined use of conventional smear and liquid-based preparation versus conventional smear for thyroid fine-needle aspiration.

Authors:  Soo-Yeon Kim; Eun-Kyung Kim; Hee Jung Moon; Jung Hyun Yoon; Hyeong Ju Kwon; Mi Kyung Song; Jin Young Kwak
Journal:  Endocrine       Date:  2015-12-29       Impact factor: 3.633

9.  How can we reduce the pain associated with FNA biopsy? Comparison of parallel and perpendicular method.

Authors:  Ihsan Yuce; Mehmet Turkeli; Suat Eren; Akin Levent; Recep Sade; Mecit Kantarci
Journal:  Jpn J Radiol       Date:  2016-05-04       Impact factor: 2.374

10.  Inadequate fine needle aspiration biopsy samples: pathologists versus other specialists.

Authors:  G S Gomez-Macías; R Garza-Guajardo; J Segura-Luna; O Barboza-Quintana
Journal:  Cytojournal       Date:  2009-06-18       Impact factor: 2.091

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.