Literature DB >> 11814458

Development and validation of a quantitative ELISA for the measurement of PSA concentration.

Boris Acevedo1, Yasser Perera, Miriam Ruiz, Gertrudis Rojas, Jesús Benítez, Marta Ayala, Jorge Gavilondo.   

Abstract

BACKGROUND: Prostate-specific antigen (PSA) has been used for the diagnosis and follow up of prostate cancer (PCa).
METHODS: Mouse monoclonal antibodies (MAbs) were generated against human prostate-specific antigen (PSA) for the development of a sensitive total PSA (t-PSA) assay. Two MAbs, denoted CB-PSA.4 and CB-PSA.9, with affinities of 3.7 x 10(9) and 4.7 x 10(10) l/mol, respectively, were used to develop an enzyme-linked immunosorbent assay (ELISA) for quantifying serum t-PSA concentration.
RESULTS: The detection limit (DL) of the assay was 0.1 microg/l (n=20, mean of "zero" standard+3S.D.), and the recovery of t-PSA was 96-103%. The within-run and between-day coefficients of variation (CV) ranged from 2.1% to 3.2%, and from 2.8% to 6.3% for PSA concentrations of 10 and 1 microg/l, respectively. The equimolar detection of t-PSA and free-PSA was demonstrated by two different methods, one consisted in the comparative evaluation of a sera panel (n=9) with our enzyme-linked immunosorbent assay (ELISA) and four commercial total PSA assays and the concordance with CIS bio total PSA assay. The assay had a linear range of 0.12 to 25 microg/l.
CONCLUSIONS: The analytical performance characteristics of our PSA ELISA suggest that it will provide clinically useful PSA results, particularly when diagnostic algorithms are used.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11814458     DOI: 10.1016/s0009-8981(01)00749-5

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  4 in total

1.  Detection of protein biomarker using a blood glucose meter.

Authors:  Tian Lan; Yu Xiang; Yi Lu
Journal:  Methods Mol Biol       Date:  2015

2.  Sub-5 nm lanthanide-doped lutetium oxyfluoride nanoprobes for ultrasensitive detection of prostate specific antigen.

Authors:  Jin Xu; Shanyong Zhou; Datao Tu; Wei Zheng; Ping Huang; Renfu Li; Zhuo Chen; Mingdong Huang; Xueyuan Chen
Journal:  Chem Sci       Date:  2016-01-12       Impact factor: 9.825

3.  Detection of biomarkers using recombinant antibodies coupled to nanostructured platforms.

Authors:  Michael R Kierny; Thomas D Cunningham; Brian K Kay
Journal:  Nano Rev       Date:  2012-07-23

4.  A comparative Study of Aptasensor Vs Immunosensor for Label-Free PSA Cancer Detection on GQDs-AuNRs Modified Screen-Printed Electrodes.

Authors:  Monika Srivastava; Narsingh R Nirala; S K Srivastava; Rajiv Prakash
Journal:  Sci Rep       Date:  2018-01-31       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.